Display Panel
User Manual
5
Installation:
The Display Panel is designed to be mounted via the wall fixings or from the M10 rigging point on the
rear of the unit. The units can be used together with the quick lock connector for alignment.
DO NOT
use the quick lock connectors to hang multiple panels
The Panels SD controller (Order code: LEDJ462) has 8 RJ45 zone connections. Each one of these
connections can control a maximum of 10 panels per zone with a maximum cable length of 20m
(in total). For configurations where extra zones are required an extra controller/slave controller will be
needed dependant on the application.
Please note: the Panel requires the SD controller (Order code: LEDJ462) to operate.
The Panel will not operate stand alone.
Please note:
- The maximum number of Display panels that can be connected are as follows:
Power - 10 panels via 1 x 13A PowerCON cable followed by 9 PowerCON link cables
Installation example 1 - For instance if using 2 panels on one zone the maximum cable length between
each panel/controller must not exceed 10m.
Installation example 2 - For instance if using 5 panels on one zone the maximum cable length between
each panel/controller must not exceed 4m.
RJ45 cables sold separately and can be purchased from most Prolight Concepts dealers.
Please quote:
CABL260 – 0.5m CABL261 – 1m CABL262 – 2m CABL263 – 5m CABL264 – 10m
PowerCON link cables sold separately and can be purchased from most Prolight Concepts dealers.
Please quote:
CABL234 – 1m CABL235 – 1.5m CABL236 – 2m CABL238 – 5m CABL239 – 10m
Installation
PowerCON
output
RJ45 signal
input
RJ45 signal
input
Controller
RJ45 signal
output
PowerCON
input
PowerCON
input
10m
10m
PowerCON
output
PowerCON
output
PowerCON
output
PowerCON
output
RJ45 signal
input
RJ45 signal
input
RJ45 signal
input
RJ45 signal
input
RJ45 signal
input
Controller
RJ45 signal
output
RJ45 signal
output
RJ45 signal
output
RJ45 signal
output
PowerCON
input
PowerCON
input
PowerCON
input
PowerCON
input
PowerCON
input
4m
4m
4m
4m
4m