Setting the DMX address

The DMX mode enables the use of a universal DMX controller. Each fixture requires a 

“start address” from 1- 511. A fixture requiring one or more channels for control begins to read the 

data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 

channels of DMX and was addressed to start on DMX channel 100, would read data from 

channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used 

do not overlap. E.g. the next unit in the chain starts at 107.

DMX-512: 

• DMX (Digital Multiplex) is a universal protocol used as a form of communication between 

intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the 

controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the 

DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have 

a data “out” terminal).

DMX Linking: 

• DMX is a language allowing all makes and models of different manufactures to be linked to-

gether and operate from a single controller, as long as all fixtures and the controller are DMX com-

pliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the 

shortest cable path possible. The order in which fixtures are connected in a DMX line does not 

influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be 

placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a 

fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to 

address 1 to that unit, no matter where it is located in the DMX chain.

DATA Cable (DMX cable) requirements (for DMX operation):

• The LEDJ Alu Par Compact Series can be controlled via DMX-512 protocol. The DMX address 

is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR 

connector for data input/output (figure 1). 

 

Figure 1

Also remember that DMX cable must be daisy chained and cannot be split.

Содержание LEDJ178

Страница 1: ...Order Code LEDJ178 Black Order Code LEDJ179 White ALU PAR COMPACT CW WW...

Страница 2: ......

Страница 3: ...dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctua...

Страница 4: ...ool white and Warm White LEDs 0 100 dimming and variable strobe 4 dimming curves Linear square law inverse square law and S curve 4 push button menu with LED display Beam angle 25 Power consumption 30...

Страница 5: ...to your chosen setting press the ENTER button to show FS01 FS99 and use the UP and DOWN buttons to increase or decrease the strobe speed 00 off 99 fast DMX mode To set the unit in DMX mode press the...

Страница 6: ...H6 Function Cool White Warm White Master Dimmer 0 100 Strobe slow to fast 17 Colour Temperature Macro Selector Function Cool White Warm White Master Dimmer 0 100 Strobe slow to fast 17 Colour Temperat...

Страница 7: ...have a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked to gether and operate from a single controller as long as all fixtures and...

Страница 8: ...viour Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in plac...

Отзывы: