Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL 
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 100~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: One year from date of purchase.

Содержание Fresco 12 RGBW

Страница 1: ...Order code LEDJ268 Fresco 12 RGBW Exterior Fixture User Manual...

Страница 2: ...t and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable s...

Страница 3: ...nting brackets complete the fixtures sleek modern appearance 12 x 3W quad colour LEDs RGBW Beam angle 15 x 37 1 421 Lux 2m full on 1 1kHz refresh rate DMX channels 3 4 6 8 or 10 selectable Static colo...

Страница 4: ...OUTPUT 100 240V 50 60Hz DMX OUTPUT MENU ENTER UP DOWN POWER CONSUMPTION 58W Fresco 12 RGBW www prolight co uk 02 08 03 06 05 04 07 08 09 09 02 01 Fuse The Fresco 12 RGBW is fitted with an internal mai...

Страница 5: ...06 FLOW2 Flow 2 Mode 07 FLOW3 Flow 3 Mode 08 FLOW4 Flow 4 Mode FLOW INVERT OFF ON Flow Direction Invert STATIC COLOR RED ORANGE YELLOW GREEN CYAN BLUE PURPLE WARM WHITE COOL WHITE Static Colour Mode M...

Страница 6: ...gs TEMP INFO C Fixture Temperature FIRMWARE V Fixture Version Value CH1 CH2 CH3 000 008 R No function Master dimmer 0 100 009 Strobe slow fast when CH1 is between 009 149 Speed slow fast when CH1 is b...

Страница 7: ...255 Blue dimmer 0 100 8 000 255 White dimmer 0 100 8 channel mode Channel Value Function 1 000 255 Red dimmer 0 100 Left Half 2 000 255 Green dimmer 0 100 3 000 255 Blue dimmer 0 100 4 000 255 White d...

Страница 8: ...e DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not infl...

Страница 9: ...pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin X...

Страница 10: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Страница 11: ...www prolight co uk Fresco 12 RGBW User Manual 11...

Страница 12: ...www prolight co uk Fresco 12 RGBW User Manual 12...

Отзывы: