Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in  
the chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output,  
see images below.

 
 
 
Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:

CABL10 – 2m

CABL11 – 5m

CABL12 – 10m

3-Pin:

CABL185 – 2m

CABL187 – 5m

CABL188 – 10m

5-Pin:

Содержание FOLL013

Страница 1: ...Order code FOLL013 FS300 LED Followspot User Manual...

Страница 2: ...in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment i...

Страница 3: ...24 12 2 141 lux 10m 24 428 lux 10m CRI 95 15kHz refresh rate Manual dimming potentiometer Manual focus and zoom Manual iris Gobo slot Gobo size 74 5mm Image size 65mm Max thickness 2mm DMX channels 1...

Страница 4: ...www prolight co uk FS300 LED Followspot User Manual 4 460mm 315mm 62mm 855mm 920mm Technical specifications 197mm 168mm 248mm 1 2 0 m m 168mm 246mm 223mm 558mm 305mm...

Страница 5: ...input 11 PowerCON output 12 Fuse F3A 250V 13 Hanging bracket 14 Hanging bracket adjustable knob 15 Positioning handles In the box 1 x fixture 1 x glass gobo 1 x colour changer magazine 1 x power cabl...

Страница 6: ...OFF Master Mode Setting Slave Slave ON OFF Slave Mode Setting Dim Curves Dim Curves Linear Dimming Curve Setting Square Square Inverse S Curve Display Screen Saver Delay OFF 01 10 Screen Saver Delay S...

Страница 7: ...e required channel mode 01ch Press the button to confirm the setting To exit out of any of the above options press the button DMX Fail To access the DMX Fail mode press the icon on the touchscreen dis...

Страница 8: ...ccess the Screen Saver Delay setting press the icon on the touchscreen display Use the and buttons to highlight Display Press the button and use the and buttons to highlight Screen Saver Delay Press t...

Страница 9: ...play Use the and buttons to select the required brightness 000 255 Press the button to confirm the setting To exit out of any of the above options press the button LED Temperature To access the LED Te...

Страница 10: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Страница 11: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Страница 12: ...started Please note Caution should be used when power linking other fixtures to the FS300 LED Followspot as the power consumption of other fixtures will vary Fixtures fitted with lamps often require 2...

Страница 13: ...ossible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Страница 14: ...www prolight co uk FS300 LED Followspot User Manual 14...

Страница 15: ...www prolight co uk FS300 LED Followspot User Manual 15...

Страница 16: ...www prolight co uk FS300 LED Followspot User Manual 16...

Отзывы: