background image

1. Detection range

2. Time setting 3. Twighlight switch setting

1. Detection range setting Ø 2 m - Ø 16 m 

Detection range is the term used to describe the diameter of the more or less

circular detection zone produced on the ground after mounting the sensor

at a height of 2.5 m, turn the detection control fully anti-clockwise to

select minimum detection range (approx.Ø 2 m), and fully clockwise to

select maximum detection range (approx. Ø 16 m).   

Note: 

The above detection range is gained in the case of a person who is between

1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if 

person’s stature, figure and moving speed change, the detection range will also change. When use this product, please adjust the 

sensitivity to an appropriate position you need, please do not adjust the sensitivity to maximum, to avoid the product does not

work normally caused by wrong motion.

2. Time setting 8 sec.- 12 min.

The light can be set to stay ON for any period of time between approx. 8 sec (turn fully anti-clockwise) and a maximum of 12 min (turn 

fully clockwise). Any movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time 

for adjusting the detection zone and for performing the walk test.

Note: 

After the light switches OFF, it takes approx. 1 sec before restart detecting movement. 

3. Light-control setting (twilight switch) 2-2000 lux

The chosen light response threshold can be infinitely from approx. 2-2000 lux. Turn it fully anti-clockwise to select dusk- to-dawn ope-

ration at about 2 lux. Turn it fully clockwise to select daylight operation at about 2000 lux.

Note: 

The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight.

Troubleshooting

Caution! Turn adjusting screws carefully until it stops. Only 270° turn possible. 

When excessive force overwind the stops, resulting in a defect!

Settings

2,5 - 3,5m

max. 16m

360°

min. 2m

Malfunction

Cause

Remedy

The load will not work

wrong light-control setting selected

Adjust setting

load faulty

Change load

main switch OFF

Switch ON

The load works always

continuous movement in the detection zone

Check zone setting

The load works without any identifiable 

movement

sensor not mounted for detecting movement reliably

Securely mount enclosure

movement occurred, but not identified by the sensor (move-

ment behind wall, movement of a small object in immediate 

lamp vicinity etc.)

Check zone setting

The load will not work despite

movement

rapid movements are being suppressed to minimize malfunc-

tioning the zone you have set is too small

Check zone setting

Ledino

 

Deutschland GmbH

the energy saving company

Spitzahornweg 1

14974 Ludwigsfelde / Berlin 

Germany

IP20

Used units must not be disposed of with household waste!

If the unit is no longer operational, every consumer is required by law to dispose of used 

devices separate from household waste, e. g. at a collection point run by the communal 

authority borough. In this way, used devices can be recycled and waste materials disposed 

of in an environmentally friendly manner. For this reason, electrical equipment is labelled 

with the displayed symbol.

We hereby confirm that the products are in line with the regulations – and in 

particular with the protection requirements – of the European Union’s directive 

on the harmonisation of the legislation relating to electromagnetic compabili-

ty (2014/30/EU), of the directive on radio equipment and telecommunications 

terminal equipment (2014/53/EU), the low voltage directive 2014/35/EU, the 

directive for Energyrelated Products 2009/125/EG and the RoHS directive 

2011/65/EC.

Statutory warranty 2 years

Отзывы: