1. Detection range
2. Time setting 3. Twighlight switch setting
1. Detection range setting Ø 2 m - Ø 16 m
Detection range is the term used to describe the diameter of the more or less
circular detection zone produced on the ground after mounting the sensor
at a height of 2.5 m, turn the detection control fully anti-clockwise to
select minimum detection range (approx.Ø 2 m), and fully clockwise to
select maximum detection range (approx. Ø 16 m).
Note:
The above detection range is gained in the case of a person who is between
1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if
person’s stature, figure and moving speed change, the detection range will also change. When use this product, please adjust the
sensitivity to an appropriate position you need, please do not adjust the sensitivity to maximum, to avoid the product does not
work normally caused by wrong motion.
2. Time setting 8 sec.- 12 min.
The light can be set to stay ON for any period of time between approx. 8 sec (turn fully anti-clockwise) and a maximum of 12 min (turn
fully clockwise). Any movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time
for adjusting the detection zone and for performing the walk test.
Note:
After the light switches OFF, it takes approx. 1 sec before restart detecting movement.
3. Light-control setting (twilight switch) 2-2000 lux
The chosen light response threshold can be infinitely from approx. 2-2000 lux. Turn it fully anti-clockwise to select dusk- to-dawn ope-
ration at about 2 lux. Turn it fully clockwise to select daylight operation at about 2000 lux.
Note:
The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight.
Troubleshooting
Caution! Turn adjusting screws carefully until it stops. Only 270° turn possible.
When excessive force overwind the stops, resulting in a defect!
Settings
2,5 - 3,5m
max. 16m
360°
min. 2m
Malfunction
Cause
Remedy
The load will not work
wrong light-control setting selected
Adjust setting
load faulty
Change load
main switch OFF
Switch ON
The load works always
continuous movement in the detection zone
Check zone setting
The load works without any identifiable
movement
sensor not mounted for detecting movement reliably
Securely mount enclosure
movement occurred, but not identified by the sensor (move-
ment behind wall, movement of a small object in immediate
lamp vicinity etc.)
Check zone setting
The load will not work despite
movement
rapid movements are being suppressed to minimize malfunc-
tioning the zone you have set is too small
Check zone setting
Ledino
Deutschland GmbH
the energy saving company
Spitzahornweg 1
14974 Ludwigsfelde / Berlin
Germany
IP20
Used units must not be disposed of with household waste!
If the unit is no longer operational, every consumer is required by law to dispose of used
devices separate from household waste, e. g. at a collection point run by the communal
authority borough. In this way, used devices can be recycled and waste materials disposed
of in an environmentally friendly manner. For this reason, electrical equipment is labelled
with the displayed symbol.
We hereby confirm that the products are in line with the regulations – and in
particular with the protection requirements – of the European Union’s directive
on the harmonisation of the legislation relating to electromagnetic compabili-
ty (2014/30/EU), of the directive on radio equipment and telecommunications
terminal equipment (2014/53/EU), the low voltage directive 2014/35/EU, the
directive for Energyrelated Products 2009/125/EG and the RoHS directive
2011/65/EC.
Statutory warranty 2 years