Leda LCL20 Скачать руководство пользователя страница 14

 

14 

REMOTE CONTROLLER (OPTIONAL) 

 

The water heater can be installed with up to three remote controllers. Each remote controller 
has  two  functions  which  can  adjust  the  set  temperature  and  indicate  the  error  code  on  the 
remote controller.   

  The  set  temperature  can  be  adjusted  only  by  remote  controller  which  has  the  priority 

setting  (When  remote  controller  has  the  priority  setting,  PRIORITY  lamp  on  remote 
controller  is  lit),  and  the  other  remote  controller(s)  display  the  set  temperature.  If  you 
desire to transfer the priority setting, you can transfer it by pressing PRIORITY button only 
when there is no water flow through the water heater. (Default set temperature is 40

º

C) 

  All  models  water  heater  have  self  diagnostic  function  for  safety  and  convenience  when 

trouble  shooting.    If  there  is  a  problem  with  the  installation  or  the  unit,  it  will  display  a 
numerical  error  code  on  the remote  controller  (or  the  LED  of  the  computer  board  will  be 
blink.)    

 

MAIN REMOTE CONTROLLER MODEL MC100-AU3 

 

  MC100-AU3 must be installed inside (such as kitchen) 

due to NO water resistant. Be careful installation 
location. 

  It allows the output temperature from the water heater 

to be adjusted within the range of 37ºC to 55

º

C.  

  The temperature options are: 

37

º

C, 38

º

C, 39

º

C, 40

º

C, 41

º

C, 42

º

C, 43

º

C, 44

º

C, 

45

º

C, 46

º

C, 47

º

C, 50

º

C, 55

º

C. 

  When “BURNER ON” lamp is lit, the set temperature 

can not be adjusted to 55

º

C. If you desire to set it to 

55

º

C, you should close the hot water tap. 

 

MODEL FC100W-AU3 SHOWER CONTROLLER  
AND SC100-AU3 ENSUITE CONTROLLER  

 

  FC100W-AU3  (Shower)  and  SC100-AU3  (Ensuite) 

controllers are water resistant, however should not be 
positioned  where  can  be  splashed  directly  and  there 
should  be  caulking  between  the  surface  of  the  wall 
and the controller. 

  FC100W-AU3 is installed such as the main bathroom, 

and  SC100-AU3  is  installed  such  as  the  ensuite  bath 
room.  

  These remote controller allows the output temperature 

from the water heater to be adjust within the range of 
37

º

C to 50

º

C. 

  The temperature options are: 

37

º

C,  38

º

C,  39

º

C,  40

º

C,  41

º

C,  42

º

C,  43

º

C,  44

º

C, 

45

º

C, 46

º

C, 47

º

C, 50

º

C. 

  When  BURNER  ON  lamp  is  lit,  the  set  temperature 

can  not  be  adjusted  to  42

º

C  or  over.  If  you  desire 

those  temperatures,  you  should  close  the  hot  water 
tap. 

 

PRIORITY

BURNER ON

ON/OFF

PRIORITY

H O T

COOL

MADE IN JAPAN

Main

4 0

Main 

Shower 

PRIORITY

BURNER ON

ON/OFF

PRIORITY

H O T

COOL

MADE IN JAPAN

Shower

4 0

Ensuite 

PRIORITY

BURNER ON

ON/OFF

PRIORITY

H O T

COOL

MADE IN JAPAN

Ensuite

4 0

Содержание LCL20

Страница 1: ...Gas Water Heaters Installation and Owner Manual MODELS LCN20 LCL20 LCN26 LCL26 FOR EXTERNAL INSTALLATION ONLY...

Страница 2: ...DIAGRAM OPERATING SAFETY WATER FLOW AND WATER TENPERATURE WARANTY CONDITIONS 17 18 18 18 19 20 20 21 21 22 24 25 26 28 28 IMPORTANT This User Guide has been prepared for Installers and Servicers of t...

Страница 3: ...6 LCL26 Gas Input MJ h 160 195 Inlet Pressure kPa Nat Gas 1 13 min 2 75 max 1 13 min 2 75 max Inlet Pressure kPa LPG 2 75 min max 2 75 min max Water Supply Pressure kPa 150 min 1200 max 150 min 1200 m...

Страница 4: ...water heater is simple Burner Heat exchanger Exhaust Flow sensor Thermistor Computer board AC240V Gas valve Fan Cold water inlet Gas Hot water outlet 1 A hot water tap is turned on 2 Water enters the...

Страница 5: ...86 GAS 1 14 HOT 124 POWER 34 ACCESSORIES Check that the installation manual and screws are included with the unit Screws 4 Manual DIMENSIONS AND CONNECTION POINTS GAS COLD HOT GAS HOT COLD 1 9 3 7 33...

Страница 6: ...NOT install the water heater indoors WARNING Water temperatures above 70 can cause severe burns or death from scalding Children the disabled and the elderly are at a high risk of being injured Feel t...

Страница 7: ...AS3500 4 before cutting or uncoupling existing metallic pipework It should be as close as practical to the hot water outlets to minimise heat loss and cost The water heater does not require a fireproo...

Страница 8: ...ater heating apparatus only and the final fitness of water delivered is dependent upon the quality of water supplied to this system Although the water heater is designed to operate with minimal sound...

Страница 9: ...ANCES FOR OUTDOOR HEATER LOCATIONS AS5601 Exemption from prescribe statutory requirements referred to in Figure 1 has been granted to allow multiple series of the Water Heaters to be positioned side b...

Страница 10: ...ct the unit to the gas line Always purge the gas line of any debris before connecting to the water heater Install a manual gas shut off valve between the water heater and the gas supply line The regul...

Страница 11: ...the water heater shown in the diagram to the right 4 Connect the manometer to the pressure port 5 Re open the manual gas valve Check to see that there are no gas leaks 6 Open some of the fixtures that...

Страница 12: ...flush the water line to remove all debris and after installation is complete purge the air from the line Failure to do so may cause damage to the heater There is a wire mesh filter to discourage debri...

Страница 13: ...water heater for easy access 4 Install so that the electrical power can be switched off if necessary 5 If the cord supplied with this appliance must be replaced it must be replaced with appliance wiri...

Страница 14: ...tput temperature from the water heater to be adjusted within the range of 37 C to 55 C The temperature options are 37 C 38 C 39 C 40 C 41 C 42 C 43 C 44 C 45 C 46 C 47 C 50 C 55 C When BURNER ON lamp...

Страница 15: ...tach the remote control to brittle you should use the anchor plug Connector base WARNING DO NOT locate the remote controls where they may come into contact with water DO NOT position the remote contro...

Страница 16: ...to remote terminals directly There is no polarity in the terminations DO NOT jump or short circuit wires Computer will be damaged 5 Replace the plastic cover and the front cover And connect the power...

Страница 17: ...t Do not use this water heater if any part has been submersed under water Immediately call a qualified service technician to inspect the water heater and to replace any damaged parts CAUTION IF YOU SM...

Страница 18: ...re on the remote controller 2 Set temperature which you want When adjust the set temperature with MC100 AU3 it allows the output temperature from the water heater to be adjust within the range of 37 C...

Страница 19: ...ity setting is transferred to FC100W AU3 or SC100 AU3 if the previous temperature setting which stored in FC100W AU3 or SC100 AU3 was 43 C and above it become to 42 C 3 Open a hot water tap and ensure...

Страница 20: ...hot water taps in the house Bathroom kitchen laundry room etc When the water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the unit s drain plugs Unscrew the...

Страница 21: ...al gas shut off valve 2 Turn off the power supply to the water heater 3 Close the manual water shut off valve 4 Open all hot water taps in the house Bathroom kitchen laundry room etc When the residual...

Страница 22: ...e hot water is not available when a fixture is opened Make sure the unit has 240V 50Hz power supply If you are using the remote controller is the power button turned on p 18 19 Is the gas supply valve...

Страница 23: ...topped the fan motor keeps running for 15 75 seconds in order to re ignite quickly as well as push all exhaust gas out of the flue REMOTE CONTROLLER OPTIONAL PROBLEM POSSIBLE SOLUTIONS Remote controll...

Страница 24: ...On the PCB or Temperature Remote Controllers The LED on the PCB Error Code on Remote Controller Symptom Burning LED 1 Time Blink 03 Incorrect Dipswitch Setting Gas 70 Proportional valve computer Burn...

Страница 25: ...ase button Decrease button MA X butt on MIN butto n Dipswitches Ground B K W Fuse 5A PCB Mo de l 2 6 Mo de l 2 4 Heater Thermostat Heater W W BK BK BK W W W 240 VAC Ground B R B L Y G B K W B K W BK W...

Страница 26: ...technician Force or attempted repair may result in a fire of explosion D Do not use this water heater if any part has been under water Immediately call a qualified service technician to inspect the wa...

Страница 27: ...ucts will be stored Read and follow water heater warnings and instructions If owner s manual is missing contact the retailer or manufacturer WARNING The outlet hot water temperature of the water heate...

Страница 28: ...t Put Hot W ater l mi n 5 10 15 20 5 16 3 15 8 15 4 14 9 14 5 14 1 13 7 13 4 13 1 12 7 12 4 11 6 10 4 9 5 7 5 10 19 3 18 7 18 0 17 4 16 8 16 3 15 8 15 4 14 9 14 5 14 1 13 1 11 6 10 4 8 0 15 20 0 20 0...

Отзывы: