TROUBLESHOOTING 

SYMPTOM 

POSSIBLE CAUSE 

No receive sound from TH1 

1) RX Level control not turned up 
2) Connect LED not lit 
3) Phone line from wall jack to TH1 not connected 
4) The Send to Bus dipswitch is in the Off position 

(switch to On) 

No transmit sound from TH1 
to remote site 

1) TX Level control not turned up 
2) Aux Output level control on AC1 not turned up 
3) Aux Output not connected to IN(+) and IN(-). 

Feedback or hollow sound 

1) Not enough Echo Suppression (increase Echo 

Suppression) 

2) Large variations in phone line impedance (set Auto 

Initialize On) 

SPECIFICATIONS 

Power Requirements: 

200mA at 

±

15V 

Connectors: 

Audio: Depluggable terminal blocks 
Telephone/Line: RJ-11 Modular 
Remote Control: DB-9 

Output Audio: 

100 Ohms, actively balanced 

Input Audio: 

Actively balanced, RF filtered 

Input Impedance: 

10k

, balanced 

5k

, unbalanced 

Telephone Hybrid: 

Standard hybrid transformer with DSP line return 
cancellation 

Auto Answer: 

Selectable - answers after first complete ring 

Remote Volume Control: 

Range: +6dB to -24dB and Off in 1dB steps. 
Range Limit: Selectable - No limit, 
+3dB/-6dB, +6dB/-6dB, +6dB/-12dB 

Echo Suppression: 

Selectable: Auto, 12dB, 18dB, 24dB 

Call Frequency Response: 

±

1dB 200Hz to 3.5kHz 

Caller THD (250Hz to 3.3KHz): 

Less than 0.1% (0dBu out) 

Send THD (250Hz to 3.3KHz): 

Less than 0.1% (0dBu out) 

Maximum Output Level: 

+26dBu 

10 

Содержание TH1

Страница 1: ...TH1 ACTIVE TELEPHONE HYBRID MODULE OPERATING INSTRUCTIONS and trouble shooting guide LECTROSONICS INC Rio Rancho NM...

Страница 2: ...2...

Страница 3: ...m transmit and receive signal separation In addition echo suppression based on Lectrosonics unique Adaptive Proportional Gain algorithm minimizes acoustic echo while maintaining near full duplex opera...

Страница 4: ...ny will notify you in advance that temporary discontinuance of service may be required If advance notice isn t practical the telephone company will notify the customer as soon as possible Also you wil...

Страница 5: ...Controller module The Transmit Level control allows adjustment of the transmit signal level for best operation The transmit signal is passed through a very fast attack limiter prior to being digitize...

Страница 6: ...n the mainframe until the female edge connector on the module seats firmly onto the male pins of the main bus board Four 4 machine screws are provided with the TH1 module The two screws with captive w...

Страница 7: ...eptable performance Use the other settings as necessary if too much of the received signal is acoustically coupled back out the to the transmit signal Auto Answer Selects whether the TH1 will automati...

Страница 8: ...the AC1 Controller Module OUT OUT Outputs the received audio signal This output is not normally used when the TH1 drives the MAP system Main or Aux bus MIX OUT Provides an unbalanced signal consisting...

Страница 9: ...On Volume Limit No Limit 6 If a local phone is connected originate a call to a remote site If no local phone is present someone at a remote site must call you If you are the originating site press th...

Страница 10: ...n SPECIFICATIONS Power Requirements 200mA at 15V Connectors Audio Depluggable terminal blocks Telephone Line RJ 11 Modular Remote Control DB 9 Output Audio 100 Ohms actively balanced Input Audio Activ...

Страница 11: ...exact quotation We will be happy to quote approximate charges by phone for out of warranty repairs RETURNING UNITS FOR REPAIR You will save yourself time and trouble if you will follow the steps belo...

Страница 12: ...lop we will at our option repair or replace any defective parts without charge for either parts or labor If we cannot correct the defect in your equipment we will replace it at no charge with a simila...

Отзывы: