background image

HM/E01

LECTROSONICS, INC.

14

Audio Frequency Response:

 

35 Hz to 20 kHz, +/-1 dB  

(The low 

 

 

frequency roll-off is adjustable)

Signal to Noise Ratio (dB): 

(overall system, 400 Series mode)

SmartNR

No Limiting

w/Limiting

OFF

103.5

108.0

NORMAL

107.0

111.5

FULL

108.5

113.0

The dual envelope “soft”  
limiter provides exceptionally  
good handling of transients  
using variable attack and release  
time constants. The limiter reduces 
30 dB of dynamic range into 4.5 dB, 
which reduces the measured figure 
for SNR without limiting by 4.5 dB.

Total Harmonic Distortion:

 

0.2% typical (400 Series mode)

Audio Input Jack:

 

3-pin Female XLR

Phantom Power:

 

5V @ 18 mA max., 15V @ 15 mA 

 

 

max.  and 48 V @ 4 mA max., plus 

  

“OFF”

Antenna:

 

Housing and attached microphone 

 

 

form the antenna

Batteries:

 

Two 1.5 Volt AA lithium or 

 

 

rechargeable NiMH recommended

Battery Life:

 

  4.5 hours (alkaline); 12 hours 

 

 

  (lithium), 8 hours with 2500mAh NiMH

Weight:

   

  6.7 oz (190 grams) without batteries

Overall Dimensions:

 

  4.25x1.62x1.38 inches

Emission Designator:

 180KF3E

Specifications subject to change without notice. 

Operating frequencies: 

(Frequency usage varies by country)

 

Block 470 470.100 - 495.600

 

Block 19  486.400 - 511.900

 

Block 20  512.000 - 537.500

 

Block 21  537.600 - 563.100

 

Block 22  563.200 - 588.700

 

Block 23  588.800 - 614.300

 

Block 24  614.400 - 639.900

 

Block 25  640.000 - 665.500

 

Block 26  665.600 - 691.100

 

Block 27  691.200 - 716.700

 

Block 28  716.800 - 742.300

 

Block 29  742.400 - 767.900

 

Block 30  768.000 - 793.500

 

Block 31  793.600 - 819.100

 

Block 32  819.200 - 844-700

 

Block 33  844.800 - 861-900

 

Block 606 606.000 - 631.500 

 

 

 

 

 

 

(100 kHz Steps)

Frequency range:

 

256 frequencies in 100 kHz steps  

 

 

for one 25.5 MHz wide block

Channel Spacing:

 

100 kHz

Frequency selection:

 

Control panel mounted membrane 

  

switches

RF Power output:

 

50 mW (nominal)

Compatibility Modes

 

Digital Hybrid Wireless

 and IFB

Pilot tone:

 

25 to 32 kHz; 3 kHz deviation  

 

 

(in Digital Hybrid mode)

Frequency stability:

 

± 0.002%

Deviation:

 

± 50 kHz max. (in 400 Series Mode)

Spurious radiation: 

60 dB below carrier

Equivalent input noise:

 

–125 dBV, A-weighted

Input level:

 

 

If set for dynamic mic: 

 

0.5 mV to 50 mV before limiting.  

 

 

Greater than 1 V with limiting.

 

If set for electret lavaliere mic: 

 

1.7 uA to 170 uA before limiting.  

 

 

Greater than 5000 uA (5 mA) with 

  

limiting.

 

Line level input: 

 

17 mV to 1.7 V before limiting.  

 

 

Greater than 50 V with limiting.

Input impedance:

 

300 Ohms

Input limiter:

 

Soft limiter, 30 dB range

Gain control range:

 

45 dB (Firmware rev. 1.3) 

 

 

55 dB (Firmware rev. 1.5)

Modulation indicators:

 

Dual bicolor LEDs indicate modulation 

 

 

of –20, -10, 0, +10 dB referenced to  

 

 

full modulation.

Controls:

  

Control panel with LCD and four  

 

 

membrane switches.

Low frequency roll-off:

 

Selectable; -3dB at 35, 50 or 70 Hz.

Specifications and Features

Содержание HM/E01

Страница 1: ...HM E01 Plug On Transmitter With Digital Hybrid Wireless Technology US Patent 7 225 135 INSTRUCTION MANUAL Rio Rancho NM USA www lectrosonics com Fill in for your records Serial Number Purchase Date ...

Страница 2: ...HM E01 LECTROSONICS INC 2 ...

Страница 3: ...cy Blocks 5 RF Isolator 5 Battery Installation 6 Attaching and Removing a Microphone 6 Operating Instructions 7 Power Up and Boot Sequence 7 Power Down 7 Automatic Power Restore 7 Standby Mode 7 Selecting the Compatibility Mode 7 Selecting the Audio Polarity 7 Adjusting the Low Frequency Roll off 8 LCD Backlight Settings 8 Setting Transmitter Operating Frequency 8 Locking or Unlocking the Control ...

Страница 4: ...e digital domain even though the inputs and outputs are analog General Technical Description Channel noise still impacts received signal quality and will eventually overwhelm a receiver Digital Hybrid Wireless simply encodes the signal to use a noisy channel as efficiently and robustly as possible yield ing audio performance that rivals that of wholly digital systems without the power and bandwidt...

Страница 5: ...tter can also be used with IFB receivers Control Panel The control panel includes four membrane switches and an LCD screen to adjust the operational settings Multi color LEDs are used to indicate audio signal levels for accurate gain adjustment and for battery status Wide Band Deviation 50 kHz deviation improves the signal to noise ratio and audio dynamic range of a wireless system dra matically c...

Страница 6: ...dicate the battery status The point at which the LED turns red varies considerably The red LED will begin to blink when there is about 30 or 40 minutes remaining 1 6 1 4 1 2 1 0 8 2 4 6 8 Hours Voltage Varies Green Red Blink Attaching and Removing a Microphone The spring loaded coupler under the XLR jack main tains a secure fit to the microphone jack with continu ous pressure applied by an interna...

Страница 7: ...pat ibility mode setup screen Press either the AUDIO or FREQ button to enter the AP audio polarity setup screen Use the UP and DOWN arrows to select the desired polarity The character P denotes positive polarity and the character n de notes negative polarity NOTE The audio polarity can also be reversed at the output of most Lectrosonics receivers Operating Instructions Power Up and Boot Sequence S...

Страница 8: ...trol panel Modulation LEDs accurately indi cate the modulation level and limiter activity Input level LEDs Once set the transmitter s audio level setting should not be used to control the volume of your sound sys tem or recorder levels This gain adjustment matches the transmitter gain with the microphone output level the user s voice level and the position of the micro phone The input gain can be ...

Страница 9: ...h resistance in the power supply feeds to pins 2 and 3 This protects the supply if the sup ply current is accidentally shorted to ground and also keeps the microphone from being attenuated by the power supply The HM improves on those functions and is able to use less power from the battery by us ing constant current sources and current limiters With this dynamic arrangement the HM can also supply ...

Страница 10: ...Adapts Lectrosonics headset and lavalier micro phones equipped with 5 pin TA5F plugs to work with Lectrosonics plug on UH and HM transmitters Converts 4 5 Volt phantom power provided by plug on transmitter to DC bias voltage needed by Lectroson ics electret microphones Internal Zener Diode protects microphone from greater than 6 Volt phantom power on XLR jack 21750 ADAPTER Polarity reversing barre...

Страница 11: ...Digital Hybrid Plug On Transmitter Rio Rancho NM 11 Compliance Documents ...

Страница 12: ...o great 7 Defective transmitter antenna unit needs repair NO SOUND OR LOW SOUND LEVEL RECEIVER INDICATES PROPER AUDIO MODULATION 1 Receiver output level set too low 2 Receiver output disconnected or cable defective or mis wired 3 Sound system or recorder input is turned down DISTORTED SOUND 1 Transmitter gain audio level is far too high Check HM LEDs and receiver audio levels as HM is being used 2...

Страница 13: ...problem Try a different operating frequency Loc APPEARS IN DISPLAY WHEN ANY BUTTON IS PRESSED Control Panel is locked See Operating Instructions Locking and Unlocking the Control Panel Hold APPEARS IN DISPLAY WHEN ARROW BUTTONS ARE PRESSED Reminder that it is necessary to hold down the AUDIO or FREQ button to make adjustments to the audio gain or frequency settings PLL APPEARS IN DISPLAY Indicatio...

Страница 14: ...800 614 300 Block 24 614 400 639 900 Block 25 640 000 665 500 Block 26 665 600 691 100 Block 27 691 200 716 700 Block 28 716 800 742 300 Block 29 742 400 767 900 Block 30 768 000 793 500 Block 31 793 600 819 100 Block 32 819 200 844 700 Block 33 844 800 861 900 Block 606606 000 631 500 100 kHz Steps Frequency range 256 frequencies in 100 kHz steps for one 25 5 MHz wide block Channel Spacing 100 kH...

Страница 15: ... warranty repairs Returning Units for Repair For timely service please follow the steps below A DO NOT return equipment to the factory for repair without first contacting us by email or by phone We need to know the nature of the problem the model number and the serial number of the equipment We also need a phone number where you can be reached 8 A M to 4 P M U S Mountain Standard Time B After rece...

Страница 16: ...item Lectrosonics Inc will pay for the cost of returning your equipment to you This warranty applies only to items returned to Lectrosonics Inc or an authorized dealer shipping costs prepaid within one year from the date of purchase This Limited Warranty is governed by the laws of the State of New Mexico It states the entire liablility of Lectrosonics Inc and the entire remedy of the purchaser for...

Отзывы: