Lectranator Systems DIG48 Скачать руководство пользователя страница 7

  Section 2a – 

INSTALLATION

 

 

 

Main Components 

Tri-Sensor Assembly 

DIG 48 = RC7 Cell 

 
 

union 

 

 

  Flow In 

 

Flow Out to  pool 

 

 

 

Control Box 

Flow Bypass Manifold Assembly 

 

CONTROL BOX 

converts incoming 

ELECTROLYTIC CELL 

TRI-SENSOR ASSEMBLY 

AC power to a Low Voltage DC current, 

receives Low Voltage DC current from 

ensures that adequate flow, 

which energizes the Cell(s). Set the 

the Power Circuit Board, which initiates 

94.5 L/min. (25 US Gallons/min.) 

Control Box 

on a vertical surface away 

the electrolytic process. This process 

minimum; 

salt

, 2.8 – 3.2 gm/l 

from excessive exposure to heat and 

converts ordinary table salt (Sodium 

(2800–3200 ppm) ideal range; and 

moisture. Use the template to mark and 

Chloride) to 100% Pure Sodium 

water temperatures

, above 

drill the (4) mounting holes and insert 

Hypochlorite (Chlorine Bleach) or 

15.6 

C (60

F) are satisfactory to 

the screws, leaving a ¼ in. gap. Hang the 

Bromine (with the addition of Sodium 

prevent abusive conditions for the 

control box on the screws and level. 

Bromide), which in turn sanitizes your 

cell to operate. See page 12 for 

Remove the cover by following the steps 

pool or spa. 

instructions to remove and inspect 

on page 12 to access the mounting 

See page 10 for salt requirements. 

the tri-sensor assembly. 

holes to tighten the screws. 

 

RATINGS: 

Input Power: 115 VAC (3.0 AC amps) 

MaximumOutput:Equivalent to 0.82 kg (1.80 lbs) of free available chlorine/day 

230 VAC (1.5 AC amps) 

 

RC-7 Cell@ Power Level 3 (8 amps DC) 

50/60 Hz 

Cell Life Expectancy: A minimum of 15,000  ampere/hours 

Output Power: Cell Power 1 (5.0* DC amps) Agency Approvals: NSF, ETL us, ETL c, CE 

Cell Power 2 (6.5* DC amps) 
Cell Power 3 (8.0* DC amps) Internal Pump Relay is rated for 30-amp max. 

*Indicates nominal amperage output. The dual axis controller will slightly vary the amps to optimize the power to the cell.  

 

The cell and tri-sensor are located in a Flow Bypass Manifold Assembly. 3.6 m (12 ft.) of 

Cell and Tri-Sensor cords 

are 

provided with the unit. Ensure that the manifold  is located within that distance from the control box with enough slack to 
allow for removal for service or maintenance. 

 

The Digital display provides full information and diagnostic for maintenance and operation of your system. The programmable 
settings are retained on a microprocessor chip with the clock setting backed-up with a CR-2025 lithium battery. 

CAUTION: 

It is suggested to locate the cell downstream of all other equipment and on the pool return line only to avoid 

over-saturation conditions of your spa. For applications other than as recommended, contact the factory.  

Содержание DIG48

Страница 1: ...FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATOR SYSTEMS INC 2770 24 Avenue N E Calgary Alberta T1Y 6V9 Phone 1 866 517 7584 REGISTRATION NO 27844 PEST CONTROL PRODUCTS ACT LECTRANATOR DIGITAL MODEL DIG48 Chlorine or Bromine Generating One DIG48 unit can treat a maximum of 153 000 Liters...

Страница 2: ...ry Alberta T2E 8V9 Cell Model RC 7 This is a replacement cell for the chlorine or bromine generating devices Lectranator Soft Touch Model ST48 REGISTRATION NUMBER 27841 PEST CONTROL PRODUCTS ACT and Lectranator Digital Model DIG 48 REGISTRATION NUMBER 27844 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Phone 1 866 517 7584 PP ST48 DI...

Страница 3: ...nd Algae In Swimming Pool Waters For Indoor or Outdoor Use RETAIN MANUAL FOR FUTURE REFERENCE C IMPORTA N N S T F50 READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the directi...

Страница 4: ...6 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet www lectranator com Manufactured for Lectranator Systems Inc 1034 72 Avenue N E Calgary Alberta Canada T2V 8V9 Lectranator Digital Model DIG 48 by LECTRANATOR SYSTEMS INC Control Unit Serial Number Cell Serial Number Model RC 7 Installer Date of Installation Control Unit Model Number DIG48 Cell ...

Страница 5: ...e with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adultsupervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Lectranator Digital Model DIG 48 to connect a minimum 8 4...

Страница 6: ...ensor Connections Remote ORP Connections 2b Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Display Panel 7 9 3b Pool Water Preparation 10 Salt Requirement Chart Start Up Procedures 3c Monitoring and Maintenance 11 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Control Box and Fuse Locations 12 Tri Sens...

Страница 7: ...ng See page 10 forsalt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 82 kg 1 80 lbs of free available chlorine day 230 VAC 1 5 AC amps RC 7 Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum of 15 000 ampere hours Output Power Cell Power 1 5 0 DC amps Agency Approvals NSF ETL us ETL c CE Cell...

Страница 8: ...ion to the LOAD SIDE of your time clock electronic controller switch or relay to work in conjunction with your circulation pump For control of your main circulation pump single or two speed through the Lectranator Digital Model DIG 48 s Internal Relay cut and strip the pre wired Line In wires and jump 1 to 3 and 2 to 4 Gr Yel can be discarded Route a new set of Pump AC Line IN wires from the circu...

Страница 9: ...lowing this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf bal...

Страница 10: ...until the end of the cycle or when manually discontinued When Boost is activated with External Timer setting programmed the time remaining for the boost cycle is held in memory and will start up in Boost mode until expired With Pump Program or 2 Speed Pump setting programmed the time clock will be over ridden producing sanitizer until the end of the boost cycle The display will indicate the BOOST ...

Страница 11: ...ric displays volume in gallons or cubic meters salt additions in lbs or kg Back Main Menu 2 0 2 2 Temperature Units displays the water temperature in Fahrenheit or Celsius Back Main Menu 2 0 2 3 12 24 hour Time displays the current time in 12 hour Time or 24 hour Time units Back Main Menu 2 0 2 4 Set Time of Day sets the time as follows Set Hours Set Minutes 2 5 Pump Program 1 allows you to progra...

Страница 12: ...onsolution 3 8 Replace Cell Only used when replacing cells May be used to zero the amp hour counter Consult Lectranator Systems Inc for details 3 9 Back Main Menu returns to MAIN MENU 4 0 INSTALLER MENU Hold Select for 10 seconds to enter this mode Use UP DOWN ARROW and SELECT to scroll through the sub menu After completing a step it displays the next step 4 1 English Metric displays volume in gal...

Страница 13: ...s in the salt Ensure that ANY salt you use contains a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Pool...

Страница 14: ...acid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL Your Lectranator Digital Model DIG 48 works most efficiently with salt levels between 2 8 3 2 gm l 2800 3200 ppm If it falls below 2...

Страница 15: ... electrical connections and fuses Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 F3 Control Panel Circuit Board Fuse Cell Fuse 3 Amps 250 VAC 10 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet...

Страница 16: ...be treated with a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use TABEX LectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the cal...

Страница 17: ...ns and Cord ordered separately Red Cap Plug for RC 7 cell cord 19050 12 ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separat ely DirectionalFlowIndicator View of locking Quick connect heads 12 ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt ...

Страница 18: ...and corrosion 4 Premature Cell Failure Requires Replacement Cell A Abnormally high Cell usage due to an insufficient A Check the stabilizer level and adjust to recommended levels Stabilizer Cyanuric acid level B ExcessiveScale DebrisintheCell B See Section 2 above C Cell Type selection not matched to the Cell installed C Follow the INSTALLER SETUP instructions see page 8 5 White Flakes in the Wate...

Страница 19: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Отзывы: