Specifications
Outputs
Model AC3 Cell Maximum output of Sodium Hypochlorite equivalent to 0.11 kg. of chlorine @3.0
Amps per 24 hours @max. dial setting of 100%
Model AC5 Cell Maximum output of Sodium Hypochlorite equivalent to 0.22 kg. of chlorine @3.0
Amps per 24 hours @max. dial setting of 100%
Flow Rate
Minimum: 57 Litres per minute.
Maximum: 189 Litres per minute. (USE EXTERNAL BYPASS IF
FLOW RATE EXCEEDS 189 L.P.M.)
Specifications
Reverse Polarity Function ( Standard in all models)
The Reverse Polarity Function is designed to automatically clean the cell blades, maximizing the
cell's ability to manufacture chlorine or bromine.
This feature is only enabled when the GREEN OK indicator is flashing. Since the OUTPUT
CONTROL DIAL affects the amount of time the GREEN OK indicator is flashing, it also has the
same effect with regards to the Reverse Polarity Function. See table below.
OUTPUT DIAL
TIME
0
DOES NOT REVERSE
25%
Every
15
hrs.
50%
Every
12
hrs.
75%
Every
9 hrs.
100%
Every
6 hrs.
ALL MODELS INPUT:
105 – 125 VAC, 50/60 HZ, 1.0 Amp for Model AC3-1 or AC5-1
210 – 250 VAC, 50/60 HZ, 0.5 Amps for Model AC3-2 or AC5-2
Automatic Self Cleaning Feature