background image

Probe PP006A 

 

The PP006A is a high impedance passive probe with a wide range of probing accessories. It 

is designed to give high impedance probing capability to a circuit when attached to a LeCroy 

Oscilloscope. 

 

System BW (

3dB) : 

500 

MHz 

System Attenuation 

:  10

×±

2% 

System Input Resistance 

:  10 M (

Ω

) // 12 pF 

Compensation Range 

:  13 pF to 23 pF 

Cable Length 

:  1.2 meters, Connector type BNC 

Max. non-destructive input voltage  :  600 V (DC + Peak AC) (see derating curve) 

Probe Sense 

:  Yes 

 

4

3

1

2

5

6

 

 

A

 

ccessories Table 

Item PP006A 

PK116 accessory 

package 

 Sprung hook 

 Ground lead (11 cm) 

 Ground lead on probe tip 

 IC Insulating tip 

 Color marking band (yellow, red, blue, green) 

4

×

2 4

×

 Trimmer tool 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание PP006D

Страница 1: ...10 M Ω 12 pF Compensation Range 13 pF to 23 pF Cable Length 1 2 meters Connector type BNC Max non destructive input voltage 600 V DC Peak AC see derating curve Probe Sense Yes 4 3 1 2 5 6 Accessories Table Item PP006A PK116 accessory package Sprung hook 1 1 Ground lead 11 cm 1 1 Ground lead on probe tip 1 1 IC Insulating tip 1 1 Color marking band yellow red blue green 4 2 4 2 Trimmer tool 1 1 www...

Страница 2: ...he time base and volts div settings until the signal on the screen contains two cycles see figures below Use the Trimmer tool 6 to adjust the probe response to match the correct trim shown below Note Do not apply excess pressure to the screwdriver when you use it The tip of screwdriver are is easy to brake because of made by plastics Undershoot Correct Overshoot Typical Voltage Derating Curve Typi...

Страница 3: ...or condition that could possibly cause bodily injury or death WARNING Usage The probe is intended to be used only with instruments which are connected to earth ground through the input BNC connector Connect the grounding terminal of the probe to the ground potential of a device to be measured WARNING Do not disconnect the probe while it is connected to a voltage source Do not directly touch a meas...

Страница 4: ...free of debris before inserting connection accessories All repair and maintenance should be referred to qualified service personnel Do not use the probe if any part is damaged Copyright January 1999 LeCroy is a registered trademark of LeCroy Corporation All rights reserved Information in this publication supercedes all earlier versions Specifications subject to change without notice www GlobalTest...

Отзывы: