background image

CTR310 - INSTRUCTIONS 

(

V1.0  28-09-2020

)

 

Electronic board controlling a 230 Vac single-phase asynchronous motor destined to sliding gate automation. 

 

Definitions 

 

Start (START) - Contact N.O. 

Input to be used to require the opening or closing of the gate.  

 

Pedestrian start (only by remote control) 

Input  to  be  used  to  require  the  partial  opening  of  the  gate. 

Pedestrian  start 

control  is  not  influent  during  a  Start  cycle  until  the  closing  step  end 

(closed gate). During a Pedestrian start cycle, 

Start 

control

 

is always working.  

 

Stop (STOP) - Contact N.C. 

It  prevents  the  start  of  working  cycle.  If  the 

Stop 

command

 

is  supplied  during  the  motion,  it  provokes  the  immediate  stop  of  the  gate.  The  gate   

remain  in  stop  as  long  as  the  contact  is  opened.  After  a 

Stop 

command

 

the  following 

Start 

command

 

always  starts  an  opening  cycle.  A 

Stop      

command supplied during the 

pause time 

interrupts the work cycle. 

 

Photocell (FOT) - Contact N.C. 

It is an optical barrier intended to intercept and signal the passage of people or vehicles along the path crossing the gate or in the area nearby it. 

The 

photocell 

is affecting but during closing step and in the 

pause  time

. If an obstacle darkens the 

photocell 

while closing it provokes the stop and 

motion reverse after 

1,5 sec.

. The intervention of the 

photocell 

during the 

pause time 

reloads it extending the period before automatic closing. 

 

Photostop (FS) - Contact N.C. 

It is an optical barrier intended to intercept and signal  the passage of people or vehicles along the path crossing the gate or in the area nearby it.    

If an obstacle darkens the 

Photostop

 during the motion or in the step previous to the work cycle start, it determines a temporary stop of the gate. 

The 

blinker

 signals by a fixed light the anomalous condition. As soon as the obstacle is removed an opening cycle starts, except when the gate is 

fully opened. In that case a closing cycle will start. The intervention of the 

Photostop

 during the 

pause  time 

reloads it extending the period before 

automatic closing. 

 

Opening stroke end (FA) 

Input 

N.C. 

to which to connect a device signalling when the gate has completed the opening stroke. 

 

Closing stroke end (FC) 

Input 

N.C. 

to which to connect a device signalling when the gate has completed the closing stroke. 

 

Safety rib (COSTA) 

Input to which to connect a device that, in case of impact against an obstacle, causes the gate stop and, after a 

1,5  sec

., gate reverse for 

2  sec

. It is 

possible  to  connect  resistive-type  safety  rib  (

8K2

)  or  with  electric  contact 

N.C.

.  Automatically  the  card  detects  the  type  of  connected  safety  rib. 

When  you  wish  to  change  safety  rib  type,  you  should  take  off  power  supply  mains  from  the  card  and  then  give  it  again  after  the  replacement.        

An obstacle pressing the safety rib in the step previous to work cycle start causes a temporary stop of the gate. The blinker signals with fixed light 

anomalous condition. As soon as the obstacle is removed work cycle starts.  

 

Blinker (LAMP) 

Card gives a command 

on/off 

(blink) to a lamp intended to signal danger situation caused by moving gate. Blinking logics are the following ones: 

 

 

 

Fast blinking 

(2 blinks/sec.): signals 

opening 

step

 

Slow blinking 

(1 blink/sec.): signals 

closing 

step

 

Fixed light

: signals that the gate is stopped waiting the obstacle obscuring the photocell, photostop or the safety rib is removed. 

 

Fast flash 

(2 flashes/sec.): signals the lack of connections on 

safety rib 

input

.

 

 

Motor (MOT) 

Outputs for the 

open / close 

command of the motor connected to the gate. 

 

Courtesy light (CORT) 

Continuous control for the lamp which lights the area around the gate. The lamp is lit for approx. 

2 minutes 

after the cycle has ended.  

 

Electric lock (SERR) 

Impulse control for the electric lock release. 

 

Signalling Leds 

DL1 - Programming Led (red)

: It switches 

on

 in programming step and during gate motion. 

DL2 - Stop Led (red)

: It switches 

off

 at a stop command in terminal board. 

DL3 - Opening stroke end Led (yellow)

: It switches 

off

 when the opening limit switch is activated. 

DL4 - Closing stroke end Led (yellow)

:  It switches 

off 

when the closing limit switch is activated. 

DL5 - Photostop Led  (yellow)

: It switches 

off 

when photoelectric cell is obscured. 

DL6 - Photocell Led  (yellow)

: It switches 

off

 when the photocell is obscured. 

DL7 - Start Led (green)

: It switches 

on

 at a start command in terminal board. 

 

Trimmer (RV1)

 

It regulates torque of the electric motor. Clockwise rotation increases the thrust of the gate. During the 

soft stop 

step, the regulation is disabled.

 

 

Programming keys 

P1 - 

Allows to insert/cancel the remote control codes in the memory 

P2 - 

Allows to set the pause time  

P3 - 

Allows to set the working time of the gate 

 

 

Dip-switches 

DP1 - Automatic closing 

(

ON = 

Step-by-step with automatic closing    

OFF = 

Step-by-step without automatic closing). 

DP2 must be ON.

 

DP2 - Condominium logic 

(

ON = 

Step-by-step     

OFF = 

Condominium mode) 

DP3 - Immediate closing 

(

ON = 

Step-by-step with immediate closing  

OFF = 

Step-by-step without immediate closing). 

DP2 must be ON.

 

 

Technical features 

 

Slow-down (soft stop) 

At stroke end the unit reduces the speed of the gate (

Soft stop 

function) so to avoid strong impacts.  

 

Radio receiver 

The electronic card 

CTR310

 contains a 3 channels radio receiver. The receiver can memorize up to 

100

 

codes. The channel 1 of receiver acts as 

Start

, while the channel 2 acts as 

Pedestrian Start

. The channel 3 switches on the 

Courtesy light 

for approx. 

2 minutes

.  

 

Electric power lack  

Following to a temporary electric power lack, at recovery the first 

Start

 control determines an opening cycle.  

 

Opening with Timer 

If the gate opening is controlled by a Timer, it is necessary to enable Condominium working logic.

 