background image

User's Manual

SU-320 & SU-3280

Содержание SU-320

Страница 1: ...User s Manual SU 320 SU 3280 ...

Страница 2: ...ration 4 4 1 Turn on Page 4 4 2 System Mode Selection 4 4 3 Project List 4 4 4 Project Information 5 4 5 Project Execution Option 5 4 6 IC Processing 6 4 7 IC Status on Socket 6 Chapter 5 PC Software Operation 7 5 1 Installation 7 5 2 Software Interface 8 5 2 1 Main Page 8 5 2 2 IC Status on Socket 10 5 2 3 Project Manager Pagee 12 5 2 4 Options Setting Page 12 Chapter 6 Tutorial 17 6 1 PC Softwar...

Страница 3: ... 2 Socket module is consumable The IC insertion times delicate operation and IC surface cleanliness all affect the quantity of contact between the socket and DUT IC and programming quantity When the programming fail rate increases significantly you need to check whether it s time to replace the socket module 3 When programming the programer will provide specific voltage and if IC is misplaced or y...

Страница 4: ...10 If any problem pleas stop programming at once 11 We will disclaim any responsibility for any loss or damage because of the above misuse Chapter 3 Appearance Description 3 1 SU 3280 Front panel 3 2 SU 3280 Side Panel ...

Страница 5: ...User s Manual 3 3 3 SU 320 Front panelr 3 4 SU 320 Side Panel ...

Страница 6: ...G PROGRAMMER Product description Line 2 Product model SU 3280 4 socket modules support IC up to 16 SU 320 1 socket module support up to 4 ICs Line 3 Show the system version and published date Line 4 Press any key to system mode selection page Line 1 Model name and Version Line 2 Execute Project select function Line 3 Via USB to PC execute remote function You can save up to 20 project File on SU 32...

Страница 7: ...er file check sum 8 digit HEX Line 4 Programming procedure Erase Blank Check Program Verify Protect Line 1 Part no Line 2 01 Run All Execute programming procedure Need to press Start button every time Line 3 02 Auto Run Execute auto run Just press Start button once after that once new IC is inserted it will automatically start Line 4 Clear counter for the Pass quantity Line 5 Set the sensitivity o...

Страница 8: ...s T1 T4 status T5 8 status 4 7 IC Status on Socket T1 T16 or T1 T4 Status symbol E C P V T IC process Erase Blank Check Program Verify Protect Socket Enable Socket Disable Under Auto Run new IC placed properly Under Auto Run new IC pin scan FAIL O PASS IC still on the socket o PASS IC taken off X Process fail IC still on the socket x Process fail IC taken off ...

Страница 9: ...I and DataBase have been installed When installing SU 320 USB drivers you will need to install 2 times When installing SU 3280 you will need to install 5 times The USB drivers will be placed on the USBDrv automatically as the image below shows For SU 320 it will only show one Universal IC Writer II ...

Страница 10: ...User s Manual 8 5 2 Software Interface 5 2 1 Main Page Software name and version Project icon Option icon Current project name Current model name Project file information ...

Страница 11: ... or START Execute Run All or Auto Run Disabled After ICs placed well you need to press the button for programming each time Enabled No need to press the button each time Stop the Auto Run procedure The current procedure will be completed and stop Log Show the current execute status and result Clear the log file ...

Страница 12: ...er s Manual 10 Save the log file 1 UI detect programmer ready status 2 When Auto Run place new IC status Under programming Run All programming successful Run All programming Fail 5 2 2 IC Status on Socket ...

Страница 13: ...aces new IC but does not run programming before removing the IC It will show PUT IC The green bar means the last time programming pass result and user places new IC but does not run programming before removing the IC After Auto Run programming finishes user places new IC but does not run programming before removing the IC It shows PUT IC The red bar means the last time programming fail result and ...

Страница 14: ...he page The maximum projects are up to 20 The highlight is the current programming project Add new project file on the programmer Delete the project file on the programmer Load the programming project file 5 2 3 Project Manager Page 5 2 4 Options Setting Page ...

Страница 15: ...the range Auto Clear and Save Save and clear the log if exceeding the range Limitation of The Number of Rows for Message Setting the range if the log exceed then clear or save Select Log Save Directory If you set the auto save log function the log file will save in this file If no the default is History MLOG Options Log Setting ...

Страница 16: ...test or simple LED function You can see the result on the Main log or display Options Information You can read the programmer BIOS and serial no on the page There are two BIOS on SU 3280 320 SU BIOS Main system BIOS the human machine interface LP BIOS Programming BIOS ...

Страница 17: ...h the DataBase When pressing the Execute it will update the BIOS to this unit PS When you update the BIOS LED will flash for a while After finishing the update the unit will reboot automatically There s a certain risk for updating So do not turn off the power when updating Otherwise the devise may not be able to reboot ...

Страница 18: ...User s Manual 16 Options Auto Run Interval Time Set the interval time for Auto Run checking Ignore Insert Detect Whether to ignore the Insert Detect result for IC processing ...

Страница 19: ...n software After generating the project file close the single operation software Single operation or SU software cannot be run at the same time If both of them are running at the same time it will lead to disorder and not work Step 2 Set the programmer to USB link to PC Connect USB cable to PC and the programmer ...

Страница 20: ... SU software to load the project file After loading the project file the loaded file cannot be modified If user wants to modify it you need use single operation software If the project file is on the list select it and click Load ...

Страница 21: ...tion Auto Run Step5 Start to program To press the START programming will start If you want to implement Auto Run mode remember to check Auto Run and implement START If you would like to stop Auto Run just press STOP PS At this moment the programming driver is using the project file that is not on the DataBase ...

Страница 22: ... results You can see the programming status and results of each Site on Site Status Or check all of the PASS FAIL Total numbers in the counter PS When you are using 4 IC socket module 4 ICs must be placed well before starting to program ...

Страница 23: ...ep 3 Place devices on each socket carefully and press START to process All devices are completed You can see the PASS FAIL status on the LED on the socket module or on T1 T16 symbol on the LCD Remove ICs The symbol of T1 T16 will show the status in time There are 2 ways you can select it One is to program all of the ICs after all of the ICs exchanged The other is to start programming each socket m...

Страница 24: ...op the programing procedure You can press to return to Project Execution Option menu Auto Run mode Please press START button when the first time operation After that when you place IC the programmer will start auto run procedure ...

Страница 25: ...Document No PME 121019 V 1 1 B TEL 886 2 2999 1860 15 E mail lillian leap com tw WEB www leap com tw www leaptronix com ...