Universal IC Writer User's Manual
17
4-6 Save
Saving users' specified file in a variety formats from contents of the data buffer.
4-6-1 Save File Path and File name:
The path of saving. Users can select the uploaded file or reselect by pressing
"Browse" button.The file name may not actually exist on disk, because the software
will automatically generate it when saving.
4-6-2 Save File Format
Select the file format.
4-6-3 Main Range Select Saving
Choose the scope of main memory blocks for saving file, and additional blocks will
be saved to the file.
4-7 Device Processing Procedure
The following descriptions are the action about DUT IC. All of the buttons are not light
before action and light in yellow when processing. After programming, green light means
success; red light means error.
4-7-1 Read
Reading all IC internal data(including parameter) and returning the data to
computer's buffer.
Then users can see the data on Edit window, the parameters will be checked via
path : "Option"
→
"Device Option"
4-7-2 Confirm
Confirming the data of buffer is the same as IC's.
Users can select only "PASS / FAIL"(default) or list error address and information.
(Check the Option
→
Confirm Error List, up to 999 error)
After the user check the box left to the button, the confirmation function will
implement following the "Read".
※
After checking "Confirm Error List", the system will let error address and
information list on information column.
But the IC parameter setting is not included.
File browsing
(File could not exist.)
Automatically setting to
the capacity of IC