Leaf Axial 4

 

Montageanleitung

Dear Customer,

To guarantee  the safety and correct working of the appliance, 

please read the following instructions CAREFULLY before begin-

ning the installation.

  

IMPORTANT:

Make sure that the power supply has been disconnected before 

performing the installation or electrical connection of the appli-

ance.

Installation, electrical connections and settings must be carried 

out by a qualified person in line with local regulations.

If these installation instructions are not followed the product 

may be damaged.

For optimal performance, the appliance must be installed cor-

rectly (installation of the unit, ducts and air replacement inlets).

This extractor fan is designed for the ventilation of households or 

similar premises. Do not use for any purpose other than that for 

which it was designed.

This appliance can be used by children aged from 8 years and 

above and persons with reduced physical, sensory or mental ca-

pabilities or lack of experience and knowledge if they have been 

given supervision or instruction concerning use of the appliance 

in a safe way and understand the hazards involved. Children 

shall not play with the appliance. Cleaning and user mainte-

nance shall not be made by children without supervision.

The fan is to be installed so that the blades are more than 2,3 m 

above the floor.

This extractor fan does not produce radio/television interference 

(Directive 2004/108/EC).

  Prior to piping installation, consult the municipal by-laws 

on air outlets and request permission from the person responsi-

ble for the building.

Precaution must be taken to avoid the backflow of gases into the 

room from the open gas pipe or from other open-flame devices.

The room must have adequate ventilation if this appliance is 

used simultaneously with other appliances that run on gas or 

other fuels.

Do not install the exhaust conduit (D) of the extractor fan to a 

chimney flume, ventilation pipes, hot air ducts or ducts used to 

evacuate fumes from appliances that run on gas or other fuels.

  

DO NOT

 install this product in areas with the follow char-

acteristics:

•  Excess of oil or grease.

• 

Areas with corrosive or flammable liquid gas or vapour.

•  Areas with temperatures higher than 40 °C or lower than -5 °C.

•  Areas exposed to the environment (rain, sun, snow, etc.)

•  Areas with possible obstacles that obstruct the access to the 

fan. 

The product and its parts must not be submerged in water or 

other liquids.

The IP rating is only valid if the installation of the appliance com-

plies with what is indicated in this manual.

The manufacturer declines all responsibility for personal injury 

or damage to animals or objects caused by inappropriate use of 

the appliance according to the warnings for installation, use and 

maintenance described in this instruction manual.

After finishing the installation these instructions should be given 

to the owner/user of the appliance.

The appliance must be able to be disconnected from the mains 

electricity supply after installation.

It can be disconnected by making the plug accessible or by incor-

Содержание 702616

Страница 1: ...Artikel Nr 702616 Ventilation www leaf ventilation de Leaf Axial 4 Montageanleitung...

Страница 2: ...2 Leaf Axial 4 Montageanleitung 1...

Страница 3: ...3 Ventilation Leaf Axial 4 Montageanleitung 3 2...

Страница 4: ...min 1 mm max 1 5 mm 4 Leaf Axial 4 Montageanleitung 4 5 6...

Страница 5: ...5 Ventilation Leaf Axial 4 Montageanleitung 7 8 9 10...

Страница 6: ...Level 1 Low Speed Level 2 High Speed Abb 8 Abb 8 Abb 8 Performance Curve Axial 4 6 Leaf Axial 4 Montageanleitung 11 Extra No 531298 www marley shop de...

Страница 7: ...beginnen sollten Sie die nachfolgende Anleitung AUFMERKSAM lesen um die Sicherheit und korrekte korrekte Funktionsweise des Ger ts zu gew hrleisten WICHTIG Vergewissern Sie sich vor allen Einbauarbeit...

Страница 8: ...d die im Ger t vorgesehene Durchf hrung f hren siehe Abbildung 6 Den Anschluss des Ge r ts wie im Abschnitt ELEKTRISCHER ANSCHLUSS beschrieben ausf hren Sicherstellen dass der Luftstrom nicht behinder...

Страница 9: ...auml fter wird auch dann auf der H chststufe eingeschal tet wenn der Lichtschalter des betreffenden Raums eingeschal tet wird Nach Ausschalten des Lichtschalters arbeitet das Ger t w hrend der ber die...

Страница 10: ...arf Altger te enthalten wertvolle recyclingf hige Materialien die einer Verwertung zugef hrt werden sollten und um der Umwelt bzw der menschlichen Gesundheit nicht durch unkontrollierte M llbeseitigun...

Страница 11: ...8 EC Prior to piping installation consult the municipal by laws on air outlets and request permission from the person responsi ble for the building Precaution must be taken to avoid the backflow of ga...

Страница 12: ...of the power supply correspond to the values indicated on the nameplate The appliance must be permanently connected with fixed installation wiring fitted in the wall and entering the appli ance throu...

Страница 13: ...cannot be removed without using a tool see fig 10 Make sure that the blades turn freely Cleaning and Maintenance Before cleaning make sure that the appliance is not connect ed to the electric network...

Страница 14: ...rnet address http www marley de index php id 1965 Disposal This marking indicates that this product should not be disposed with other household wastes through out the EU To prevent possible harm to th...

Страница 15: ...15 Ventilation Leaf Axial 4 Montageanleitung...

Страница 16: ...entilation eine Marke der Marley Deutschland GmbH Adolf Oesterheld Str 28 31515 Wunstorf Tel 49 5031 53 600 Mail info leaf ventilation de www leaf ventilation de 06 21 Technische nderungen vorbehalten...

Отзывы: