LeadSolar Energy Microinverter LS600 Скачать руководство пользователя страница 20

LS600 Installation and Operation Guide 

 

  20 

www.leadsolarenergy.com 

Technical Data 

8.1 

Technical Considerations

   

The LeadSolar LS600 Microinverters are electrically compatible with most 60-cell or 72-cell PV modules. Be 

sure to verify the voltage and current specifications of your PV module match those of the microinverter. For 

more information, refer to our list of compatible PV modules.   

 

 

The PV module’s maximum open circuit voltage must not exceed the 

microinverter’s maximum input voltage. 

 

 

The output voltage and current of the PV module depends on the quantity, size and temperature of the PV cells, 

as well as the isolation on each cell. The highest PV module output voltage occurs when the temperature of the 

cells is the lowest and the PV module is at open circuit (not operating). The maximum short circuit current 

rating of the PV module must be equal to or less than the maximum input DC short circuit current rating of the 

microinverter.

 

 

8.2 

Specifications

 

INPUT DATA (DC) 

LS600 

LS600-AU 

LS600-EU 

Recommended input power (STC) 

230 – 280 W 

Maximum input voltage 

60V 

MPPT voltage range (Full Power) 

27 – 45V 

Operation Voltage Range 

22 – 55V 

Maximum DC short circuit current 

15A 

Maximum input current 

9.7A x 2 

OUTPUT DATA (AC) 

LS600 

LS600-AU 

LS600-EU 

Maximum continuous output power 

500W 

Nominal output current 

2.17A/2.08A 

2.08A 

2.17A 

Nominal voltage 

230V/240V 

240V 

230V 

Nominal operating voltage range 

202–253V(for 230V) 

211–264V(for 240V) 

210 – 260V 

195.5 – 253V 

Nominal operating frequency 

50Hz/60Hz 

50Hz 

50Hz 

Power factor 

>0.99 

Total harmonic distortion 

< 4% 

Содержание Energy Microinverter LS600

Страница 1: ...LS600 Installation and Operation Guide 1 www leadsolarenergy com LeadSolar Energy Microinverter LS600 Installation Operation Guide Dec 31 2013 Ver 2 2...

Страница 2: ...fore installing operating and servicing the unit The Grid Connected Inverter meets the requirements stipulated in Low Voltage Directive LVD 2006 95 EC Waste Electrical and Electronic Equipment WEEE Di...

Страница 3: ...e 10 4 1 Preparation 10 4 2 Installation 10 Step 1 Measure Grid AC Voltage at Electrical Utility Connection 11 Step 2 Attach Microinverter to PV Racking 11 Step 3 Connect Microinverter s AC Cable 12 S...

Страница 4: ...pair or modify the LeadSolar Microinverter themselves If the microinverter fails to operate contact LeadSolar customer service for repair or replacement Tampering with or opening the hardware will voi...

Страница 5: ...n The LeadSolar Microinverter meets the product quality standards of T V S D Caution Do not come within 8 inches 20cm of the microinverter for any length of time while it is in operation Danger of hig...

Страница 6: ...cial PV applications the output power from a central inverter architecture is usually not maximized no matter how advanced PV modules or inverter technologies are used Traditional String Inverter Lead...

Страница 7: ...atically start to work and communicate with the microinverters in your system The collected system operation data will be reported to the LeadSolar Management web server The Management software presen...

Страница 8: ...with both 60 cell and 72 cell PV modules For more information see Technical Data The LS600 should only be connected to the grid type listed below Electrical Compatibility Model Number Compatible PV Mo...

Страница 9: ...ion boxes Gland or strain relief fitting one per AC junction box Continuous grounding conductor grounding washers Number 2 and 3 Phillips screwdrivers Torque wrench sockets wrenches for mounting hardw...

Страница 10: ...s should be installed by a technician 4 2 Installation Read entire installation procedure before installing The following procedure must be strictly followed for a proper installation Step 1 Measure A...

Страница 11: ...se 230V AC 195 5 253 EU 210 260 AU Distribution Panel Multimeter Check cable voltage rating before installation For LeadSolar Quick Connect cables voltage rating is marked on the cable s label Never u...

Страница 12: ...anch to the adjacent microinverter Then repeat this step for each microinverter in a branch and eventually any adjacent microinverter s AC cables should be connected Then connect the 2 nd AC cable of...

Страница 13: ...eration Guide 13 www leadsolarenergy com Never leave unused AC cables open floating in the system Terminate the unused end of an AC cable with provided protective caps Terminate the unused end of the...

Страница 14: ...ssories and proper washers 3 Pay attention to the wire colors in the cable The electrical codes usually have the following specification for the wire color Red Hot wire Black Neutral wire Ground yello...

Страница 15: ...located and place in the correct order on your drawing of the system Remember to keep a copy of the installation for your records You are not done yet Complete the Operation Guide section to begin us...

Страница 16: ...LS600 Installation and Operation Guide 16 www leadsolarenergy com Step10 Register Microinverter Go to www leadsolarenergy net For more information refer to the LeadSolar Smart Grid Web Application...

Страница 17: ...ers that registered in our website 5 Login to your user account on www leadsolarenergy com and monitor the operation of your system in real time Please note that for the first time power up after inst...

Страница 18: ...cepted AC grid conditions 2 Check the connection of the system Disconnect the AC side and then the DC input side of the microinverter 3 Check the PV module open circuit voltage The open circuit voltag...

Страница 19: ...verter to be replaced 3 Disconnect AC connection cable from adjacent microinverter 4 Disconnect PV module from microinverter 5 Remove failed microinverter from PV rack 6 Follow Installation Instructio...

Страница 20: ...tage occurs when the temperature of the cells is the lowest and the PV module is at open circuit not operating The maximum short circuit current rating of the PV module must be equal to or less than t...

Страница 21: ...LS600 EU Operating ambient temp range 40 o C to 65 o C Dimensions W x H x D 26 cm x 18 cm x 3cm Weight kg 3 5 kg Cooling Natural Convection Enclosure environmental rating IP65 OTHER FEATURES LS600 LS6...

Страница 22: ...LS600 Installation and Operation Guide 22 www leadsolarenergy com Appendix Microinverter PV System with gateway...

Страница 23: ...energy com LeadSolar Energy Co Ltd Room 402 Building A1 228 Linghu Ave Wuxi New District Wuxi China 214135 Tel 86 510 81817488 Fax 86 510 81817475 info leadsolarenergy com www leadsolarenergy com Copy...

Отзывы: