User Manual of iSV2-CAN Servo
www.leadshine.com
73
Bit
15~9
8
7
6
5
4
3
2
1
0
-
Halt
Fault
reset
-
-
Homing
operation
start
Enable
operation
Quick
stop
Enable
voltage
Switch
on
The action taken is described below, depending on the value of each bit:
Name
Value
Description
Homing
operation start
0
Do not start homing procedure
1
Start homing procedure
Halt
0
Execute the instruction of bit 4
1
Stop axis with homing acceleration
6.8.2 Statusword in profile homing mode
The binary representation of the statusword(6041) in profile homing mode is as follows:
Bit
Definition
15~14
-
13
Homing error
12
Homing attained
11
-
10
Target reached
9
-
8
Abnormal stop
7
-
6
Switch on disabled
5
Quick stop
4
Voltage output
3
Fault
2
Operation enable
1
Switch on
0
Ready to switch on
The meaning of each bit is described below, depending on its value:
Homing
error
Homing
attained
Target
reached
Description
0
0
0
Homing procedure is in progress
0
0
1
Homing procedure is interrupted or not started
0
1
0
Homing is attained but target is not reached
0
1
1
Homing mode carried out successfully
1
0
0
Homing error occurred;
Homing mode carried out not successfully;
Velocity is not zero