Hardware
Manual of the ES-D Series Drives
13
Configuration
When the default settings of the easy servo drive are not suitable for your application, it is necessary
to configure the drive via the DIP switch or ProTuner (the setup software). Otherwise you may
encounter problems like high motor heating, big motor noise or even motor stall due to weak torque.
For a quick start of the easy servo drive, there are not much parameters need to be configured. The
following table gives the most significant parameters of the easy servo drive.
Most Significant Parameters of the easy servo drive
Parameters
ES-D508
ES-D808, ES-D1008
Micro Step Resolution (PPR)
Default 4000, Software Adjustable
Default 1600, DIP Switch or Software
Adjustable
Holding Current (%)
Default 40%, Software Adjustable
Default 50%, Software Adjustable
Close-loop Current (%)
Default 100% , Software Adjustable
Default 100%, Software Adjustable
Current Loop Kp
*Auto Tuning at Power-up
*Auto Tuning at Power-up
Current Loop Ki
*Auto Tuning at Power-up
*Auto Tuning at Power-up
*
Auto Tuning at Power-up
: It is possible to disable this feature in the setup software in order to tune
the current loop Kp and current loop Ki manually if the auto tuning result is not good enough. This
happens when the motor
’
s inductance or resistance is too high or too low.
The holding current affects the holding torque when the motor is stop. The close-loop current affects
the dynamic torque. Increase them if the torque is not enough.
Recommended
Holding / Close-loop Current
Percentage
ES-M32309
ES-M32320
ES-M23440
ES-M23480
Holding Current (%)
60%
60%
60%
60%
Close-loop Current (%)
100%
100%
100%
100%
Easy servo drive
ES-D508
ES-D508
ES-D808 / ES-D1008 ES-D808 / ES-D1008
There are possible two methods to configure the easy servo drive as follows, depending on the
specific drive.