User Manual Of EL7-EC** AC Servo
170
6065
0
Position
deviation
window
RW
RxPDO
Yes
Yes
/
6066
0
Position
deviation
detection
time
RW
RxPDO
Yes
Yes
/
606C
0
Velocity
feedback
RO
TxPDO
Yes
Yes
Yes
6074
0
Internal
command
torque
RO
TxPDO
Yes
Yes
Yes
6076
0
Rated torque RO
TxPDO
Yes
Yes
Yes
6077
0
Actual
torque
RO
TxPDO
Yes
Yes
Yes
60F4
0
Actual
following
error
RO
TxPDO
Yes
Yes
Yes
60FA
0
Position
loop
velocity
output
RO
TxPDO
Yes
Yes
Yes
60FC
0
Internal
command
position
RO
TxPDO
Yes
Yes
Yes
5.5.2 Cyclic Synchronous Position Mode (CSP)
CSP Block Diagram
Position
Loop
Velocity
Loop
Current
Loop
Motor
S
M
U
L
Target position
(607Ah)
Polarity
(2006h)
Trajectory planning output
C
S
P
PP
Position feedforward
(60B0h)
Internal velocity
feedforward
Velocity feedforward
(60B1h)
Internal t
orque
feedforward
Torque feedforward
(60B2h)
PP
PP
+
+
+
+
+
+
Amplifier
Actual torque
(6077h)
Actual velocity feedback
(606Ch)
Actual position feedback
(6064h)