US
This equipment is manufactured in compliance with CE directives and ISO-9001. It should be
used only by fire-fighting professionals.
Read this manual completely, together with the attached instructions for the use and
maintenance of the engine before starting up or using the equipment.
Do not remove the gasoline tank cap, or fill the tank, while the engine is running or when it is
hot (let the engine cool down for 2 minutes before filling the gasoline tank).
Keep fingers and hands away from the turbine and the hot parts of the equipment
(cylinder block and exhaust).
Do not start up the engine when the air filter or the air filter cover are removed.
Always use recently produced unleaded gasoline. Gasoline which has been stored for a long
time forms a deposit which could block the carburettor.
Do not run the engine in an enclosed space. (The exhaust gases contain carbon monoxide.)
Do not fill the gasoline tank in an unventilated area.
This ventilator must be operated or repaired only by qualified, trained staff.
Do not start up the engine if the blades or the protective shroud show any signs of damage.
Never move the ventilator when it is running at full speed.
Only use genuine spare parts supplied by
Leader North America, Inc.
when replacing
damaged or defective parts.
During maintenance operations, the wire leading to the spark-plug should be removed and
fixed elsewhere.
MT236
type blowers must not be used in explosive atmospheres.
Do not remain in the fan’s outlet area (risk of flying debris).
Keep this equipment out of reach of children.
Wear safety glasses, gloves and earmuffs when using this ventilator.
Never allow anyone to use a ventilator without first giving them the necessary instructions.
Do not wear loose clothing which could get caught in the ventilator.
Do not use chocks or any other system for increasin
g the ventilator’s tilt angle.
Do not forget to put oil in the ventilator’s engine before use.
SAFETY INSTRUCTIONS :
PRECAUTIONS FOR USE :
NOTE
: MT236
ventilators operate on the high-speed entrained air principle. These
portable ventilators are designed to clear smoke and gas, volatile or otherwise, by their
blowing (or positive power) action, in all types of premises where an exit has been prepared.
They are designed to be used between 6 to 18 feet away from the opening concerned.
Leader North American, Inc
recommends that the minimum opening for escaping smoke
should be double or more than the size of the entry opening
This document has been drawn up in order to help you get to know how to use your
MT236
ventilator
.
All operating and safety instructions must be strictly followed in order to avoid
accidents or problems. All operations involving dismantling or repair must be carried out
by
Leader North America, Inc.
or by an approved dealer.
This document demonstrates the ease of use and maintenance of the
MT236
ventilator. If
you have any suggestions for improving this document,
Leader North America, Inc.
would
be very happy to hear them. Please do not hesitate to contact us
.
R = 19.68
“
Code Notice :
MT236.0ZN.3.33.US.0