USER MANUAL
LL FLOOD WASH
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
LL44 090
All dimensions are in milimeters
ENviRONMENt
Do not throw away the appliance with the normal household waste at the end of its life,
but hand it in at an official collection point for recycling. By doing this, you help to preserve
the environment.
WARNiNG!!!
Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only
by a qualified professional in accordance with relevant local codes.
01 SAFEty iNFORMAtiON
01.1 Risk of eyes damage
Do not look directly into LED lamps.
Do not look into light beam from a distance of less than 40 cm (16 inches)!
-
-
01.2 Protection from electric shock
Shut down power before installation or maintenance.
Luminaries and recommended AC power supply must be installed by a qualified professional
in accordance with relevant local codes. Only acceptable source of AC power and frequency
that complies with local building and electrical codes to use.
Do not use or do not connect the products if the power cable, power plug or fixtures are any
way damaged, wet, or if they are overheating.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the
warranty.
Before removing or installing any cover or part of appliance disconnect it from AC power.
Appliance always connect to earth (eltech.).
-
-
-
-
-
-
01.3 Fire prevention
Follow all safety consideration.
Thermostatic switches or fuses never to bypass.
Device never shield. Around the axis of the fitting (180°) must be maintained space for
cooling. Minimum distance from the surrounding objects must be 100mm (4 in.) (figure 1.1).
LEDs never direct cover with filters or other materials.
Allowing max. ambient temperature is 40°C (104°F).
Luminaries never use without mounting brackets.The housing never install directly to the
surface.
-
-
-
-
-
-
02 PRODUct SPEciFicAtiON
02.1 Technical Specification
03 iNStALLAtiON
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must be claim
immediately by the transport company. Photo pictures as evidence are valuable for
future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device
clusters (luminaries, clamps, cables, ...).
Hairbreadth from combustible materials is 0,5m.
-
-
03.3 connecting to Ac power
to tackle all Safety information- 01!
For protection from electric shock, the device must be grounded (earthed)!
It is not necessary to open the fixture before power supply.
Power supply is solved simple with Neutrik PowerCon connectors.
The fixture is equipped with auto-switching power supply that automatically adjusts to
any 50-60Hz AC power source from 100-260V.
Cord plug connections:
-
-
-
-
-
-
©MMX - Leader Light – All right reserved
02.2 Back panel
If you have any question please, contact [email protected]
cOMPLiMENtS ON yOUR PURcHASE!
Symbol
Pin
Wire colour
Screw (US)
L
live
brown
yellow or brass
N
neutral
blue
silver
ground (earth)
yellow/green
green
03.4 control data connecting
Control data cable length is specified by Norm IEC929 Annex E4.
It is not necessary to open the fixture before connecting of DMX512 control signal.
Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
Pin connections :
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
content:
01 SAFEty iNFORMAtiON
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PRODUct SPEciFicAtiON
02.1 Technical Specification
02.2 Back panel
03 iNStALLAtiON
03.1 Unpacking
03.2 Physical installation
03.3 Connecting to AC power
03.4 Control data connecting
03.5 DMX channels
04 MAiNtENANcE
Edition: A - 2010
LL44 100
One module RGBAW (4pcs White, 4pcs Green, 4pcs Blue, 5pcs Red, 5pcs Amber) => total 3/6 modules
Lamp type:
66/132 x RGBAW P4
*
Lifetime:
Long 50 000 hrs 70% degradation
Optic:
Standard: 25°, on request: 10°, 40°, EL and AS
control data input:
DMX 512 In/Out with XLR 5pin
input power:
max: 102W/203W
Power connection:
100-260V AC 50-60Hz In/Out PowerCon
Net weight:
5,5kg/11kg
iP:
IP20
Ambient temp. (ta):
max. +40°C
cooling:
Conventional
Materials and finish:
Housing: powder-painted anodized aluminium RAL9006
(other colours on request)
installation:
Surface mounting
*
P4: R-Red, G-Green, B-Blue, A-Amber, W-White (6300°K)
LED
iNDicAtiON
StAtUS
POWER (Red)
blinking – 2Hz
OK - inside fixture is everything correct
DATA (Green)
light off
NO DMX512 signal
DATA (Green)
blinking – 4Hz
OK- income correct DMX512 signal
DATA (Green)
fast blinking
NON correct digital signal
POWER (Red)
alternate blinking
Autotest function
DATA (Green)
control LEDs indication
POWER
DATA
Dip options
» Rotating DIP address 000÷511
“100“ “10“ “1“
DMX Out
XLR-5pin
DMX In
XLR-5pin
Power In
PowerCon
Power Out
PowerCon
Control LEDs
+
+
+
+
+
+
120
80
1200
600
Following items are included:
- LL FLOOD WASH RGBAW 5m power cable with PowerCon
1 pc.
- PowerCon type “A“
1 pc.
- PowerCon type “B“
1 pc.
- Adjustable mounting bracket
1 pc.
- User manual
1 pc.
Additional items needed:
- Data cables with XLR 5pin Female/Male
1 pc.
- Controller compatible with DMX
1 pc.
Surface mounting:
- Screws and washers M12, M10