4/8/16E1 over Ethernet aggregation Gateway

 

 

 

There  are  9  indicators  on  the  front  panel  of  the  device,  and  their  functions 

are:   

NOTICE: LOS LIGHT

      8E1, only the first 8-way effective 

                                              4E1, only the first 4-way effective 

LED 
Name 

Colors 

Functions 

Status 

Description 

PWR 

GREEN 

Power 
Indication 

on 

Power supply normal 

off 

Power off 

FB2 

GREEN 

FB2 
Indication 

on 

Fiber connected 

flash 

Device 

transmitting 

data. 

off 

Fiber Disconnected 

FB1 

GREEN 

FB1 
Indication 

on 

Fiber connected 

flash 

Device 

transmitting 

data. 

off 

Fiber Disconnected 

SYS 

YELLOW 

System status 

flash 

System working 

on 

System abnormal 

off 

System 

booting 

normally 

LOS1~16 

RED 

1-16  Channels 
Alarm 

on 

Channel loss signal 

off 

Normal 

SPD1~4 

GREEN 

Ethernet 
Speed    status 

on 

100M 

off 

10M 

ACT1~4 

YELLOW 

Ethernet 
Activity 

flash 

Device 

transmitting 

data. 

on 

Network is established 

off 

Disconnected 

Содержание MRS4604A

Страница 1: ...Panel of the Device 4 2 2 Introduction to the rear panel of the equipment 6 Chapter Three Technical Specifications 7 3 1 Operating Environment 7 3 2 Power Supply Section 7 3 3 Mechanical Specificatio...

Страница 2: ...n the Company cannot be held liable for any harm or damage resulting from any omissions inaccuracies or errors contained in the manual Brief Introduction This User Manual describes the installation an...

Страница 3: ...rnet ports The encapsulation method support HDLC PPP BCP RFC3518 GFP F 1 2 Equipment Features Support 4 port Ethernet electrical interfaces 2 port Ethernet electrical interfaces or 2 port fiber interf...

Страница 4: ...ecification 2 1 Introduction to Front Panel of the Device Figure1 E1 120 2TX 2FX Figure2 E1 120 4TX Figure3 E1 75 2TX 2FX Figure4 E1 75 4TX NOTICE 8E1 only the first 8 way effective 4E1 only the first...

Страница 5: ...off FB2 GREEN FB2 Indication on Fiber connected flash Device transmitting data off Fiber Disconnected FB1 GREEN FB1 Indication on Fiber connected flash Device transmitting data off Fiber Disconnected...

Страница 6: ...The system is in normal operation if continuously press the Reset button more than 3 seconds the system will restore factory default configuration and reboot E1 Interface Q9 75 RJ45 120 Console The d...

Страница 7: ...should be free from corrosive and solvent gases dust and magnetic interference 3 2 Power Supply Section Input Voltage AC 220V DC 48V Voltage Fluctuation 100VAC 240VAC 40VDC 72VDC Power Consumption 10...

Страница 8: ...ser input the default IP address in the address bar 192 168 0 168 As below the login dialog input the right username and password The username and password is all root 4 2 System configuration 4 2 1 S...

Страница 9: ...ver Ethernet aggregation Gateway 9 IP Address 192 168 0 168 Net Mask Default Gateway 4 2 3 Password configuration User can change password on this page and re login use the new password 4 2 4 SNMP con...

Страница 10: ...n this web page 4 2 5 Global Configuration Dot1Q Vlan Enable Vlan QinQ function enable Admin Vlan User interface VLAN QinQ Enable Double Vlan enable QinQ Ether Type Double Vlan type setup E1 QinQ Pvid...

Страница 11: ...meslot interval or their combination through the Time Slot Every Channel ID corresponding one E1 under HDLC mode E1 can t repeat 4 2 7 Ethernet configuration Config Mode Set the work mode of the Ether...

Страница 12: ...Text choice enable and click Config to check the E1 circuit is normal or not 4 2 9 Vlan enable Support 16 vlan tables Vlan table will be effective when Dot1Q Vlan function in System Config page is en...

Страница 13: ...4 8 16E1 over Ethernet aggregation Gateway 13 This page shows the E1 alarm 4 2 11 Ethernet Statistics Ethernet statistics will automatically refresh every 10s 4 2 12 Channel statistics...

Страница 14: ...istics will automatically refresh every 10s 4 2 13 System update Update the software and firmware in the page the software must be named as bin and firmware must be named as rbf NOTICE 8E1 WEB page on...

Страница 15: ...onnecting Cable adopts twisted pair line with its specific making methods divided into two international standards which are EIA TIA568A and EIA TIA568B Position the tail of crystal head downward i e...

Страница 16: ...follows 1 1 2 used to send 3 6 used to receive 4 5 7 8 are bi directional lines 2 1 2 must be pair twisted 3 6 pair twisted 4 5 pair twisted 7 8 pair twisted Making of straight through line both heads...

Страница 17: ...months since the purchase of the product 2 Can t provide certificate of purchasing date and serial No of product shows that ex works term has exceeded 36 months 3 Include but not limit to the abnorma...

Страница 18: ...4 8 16E1 over Ethernet aggregation Gateway 18 Repair and Maintenance Record Product Name Ethernet aggregation Gateway Device No Maintenance date No of Service Bill 1 2 3 4 5...

Отзывы: