Le Maitre Ltd.
Wireless SQP User Manual
3
2.1
Operational Guidance
The Wireless SQP is only suitable for indoor use, or situations that meet the same environmental
conditions.
The machine must only be used vertically, secured in position, protected from unauthorised
interference, impact forces and vibration.
Any installation or repositioning should only be performed when the machine is cool,
disconnected from the mains supply, key switch and battery isolation switch is in the OFF
position, and disconnected from all data communication.
Changing canisters should only be performed when the machine is
powered down
, the key and
battery isolation switches are both in the OFF position, and no other sources of ignition are
present. Operator must check
no residual fluid is present or alight
.
Safety distances must be given a priority when using the Wireless SQP. This includes artists,
performers, persons in both performance and audience areas, as well as surrounding flammable
objects. Maximum flame heights are presented in section 1 of this manual. Operators are
expected to use this information to determine appropriate safety distances.
Full risk assessments must be made before use, and all relevant emergency failure procedures
must be immediately available, including qualified personnel, fire extinguishers and first aid.
All operations must undergo preliminary tests and rehearsal.
Always ensure it is possible to shut the machine down immediately in case of emergency. Use of
an Emergency Stop to interrupt power supply is recommended.
Use only Le Maitre Chameleon Flame Fuel or Le Maitre Salamander Flame Fuel. Use of alternate
fuels may lead to unexpected behaviour; including but not limited to ejection of unignited fuel on
insertion of canister, failure to ignite fuel blast when firing or failure to shut down the flame
(“sticking open”). Manufacturer will not be held responsible for unexpected behaviour if machine
is ever operated with non-designated fuel; warranty will be void.