Nota Moving User’s Manual – 1.0
Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy
Tel. +39 0376 771 777 – fax +39 0376 772 140 – email
– web www.ldr.it
8
A PSU for 1 Nota Moving
B PSU for 6 Nota Moving
C Power supply cable
D Power/control
cable
E Control
desk
OPERATION
8.
DMX CONNECTION
The DMX-signal cable is connected to the XLR5 plug "DMX IN". If you need to connect the DMX
signal to additional devices, the DMX-OUT output needs to be used. In this case it is necessary to set
the DMX termination switch to "OFF". If the unit is the last one in the DMX chain, set the DMX
termination switch to "ON".
9.
CONNECTION TO THE NOTA MOVING
This connection is made with an XLR 4-control cable (maximum length 100 m), and can be
connected directly to the Nota Moving. Up to 6 Nota Moving can be connected to the DMX
Control/Power Unit No. LI 1002.06.
24VDC for the motor and electronics is provided by the PSU on the XLR4 output
10.
POWER CABLE
Cables must be connected only to unregulated power circuits (no dimmer connection). Supply
voltage can range from 85-260 VAC 50 or 60 Hz.
11.
7-SEGMENT DISPLAY
The display shows the software version in use and the start address. It lights approx. 10 seconds after
power-up and after any address change. It will then automatically switch off after that time.
12.
SETTING THE START ADDRESS
a) Press the “Select” key. The start address appears on the display and the start address flashes on
the 7-segment display.
b) By pressing the "Change" key, the start address can be increased by 1.
c) By pressing the “Select” key again you can control the decimal place.
This begins to flash.
d) With the "Change" key, select the desired value.
e) Repeat steps (c) and (d) for the hundred values.
f) After 10 seconds the display switches off and the address is stored.