background image

Cetra F & PC 100 LED  User’s Manual – 1.0 

 

 

Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy 

Tel. +39 0376 771 777 – fax +39 0376 772 140 – emai

[email protected]

 – web www.ldr.it 

 

4. CONTROL FUNCTIONS AND OPERATION 
OPERATION

:  LCD display for DMX address, system setup and status details. 

POWER

:  power LED status indicator  , red color.   ON= power  

DMX

:  DMX LED status indicator, green color.  LED OFF = DMX OFF and manual control activated , LED ON  =  DMX MODE 

activated with no DMX signal,  FLASHING   LED = receiving DMX    

MENU

: rotary switch selector to select and modify the operational modes.  Turn  left or right to navigate through the 

menu and press to select or to confirm 

DMX IN

:  input DMX signal (pin1=0 , pin2= DATA- , pin3=DATA+ ). 

DMX OUT : 

 Loop through DMX signal output 

POWER IN:  

Mains power input  

POWER OUT

: Mains power output 

FUSE

:   5x20 6.3A HPC FAST 

 

There are thirteen different operation menus for the setting of the CETRA LED  control functions.  The rotary selector is 

used to adjust the settings and to navigate through the menu structure.  Turn left or right to select the menu and push 

to access or to confirm the selected data or functions.   
 

4.1 DMX OR MANUAL (Mode):   
Select the LED  control mode  between  DMX (factory setting)  and  manual. To change  the control mode press once the 

rotary selector until an arrow (

) appears on the menu.  Turn the selector to the right or the left to select the desired 

mode of operation and press  to confirm your selection.  

 
 
 
 
Tap the rotary selector and the LCD screen will display  the mode status and the current value : 
 
 
 
 
 
 
 
 
4.2 DMX ADDRESS (Addr): 
It  allows to select the initial DMX starting  address to remotely control the LED functions. To change the initial DMX 

address press the rotary switch until an arrow appears, then turn to change to the desired DMX starting address.  Press to 

confirm your selection. Factory setting  is   

001

 
 
 
 
 
4.3 DIMMER RESOLUTION (8/16b): 
The dimming resolution can be controlled at 8 bits  from one DMX channel to 16 bits with 2 DMX channels.    
Factory  setting   

8 Bit

1 M:Manual 

XX % 

1 M:DMX 

XX % 

1 Mode 

DMX 

1 Mode 

MANUAL

 

     

TAP THE ROTARY 

SELECTOR TO DISPLAY 

THE  VALUE 

TAP THE ROTARY 

SELECTOR TO DISPLAY 

THE  VALUE 

00 % = LED OFF  

FF %  = LED FULL 

00 % = LED OFF  

FF %  = LED FULL 

2 Addr 

001     

PRESS TO ACTIVATE 

THE MENU  AN 

ARROW SHOULD 

APPEAR  

1 Mode 

DMX 

1 Mode 

DMX   

     

1 Mode 

MANUAL   

     

TURN  TO SELECT 

MANUAL OR DMX 

AND PRESS TO 

CONFIRM 

2 Addr 

001   

     

1 Addr 

###     

TURN  TO ASSIGN 

THE DMX ADDRESS 

AND PRESS TO 

CONFIRM 

PRESS TO ACTIVATE 

THE MENU  AN 

ARROW SHOULD 

APPEAR  

Содержание Cetra F100 C

Страница 1: ... PC100 W LED 3200K Cetra PC100 C LED 5600K istruzioni per l uso operating instructions Bedienungsanleitung instrucciones de manejo mode d emploi gebruiksaanwijzing Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Страница 2: ...TION Local control panel and operation 4 4 1 DMX or manual 4 4 2 DMX address 4 4 3 Dimmer resolution 4 4 4 DMX frequency control 5 4 5 Lost DMX signal 5 4 6 Strobe 5 4 7 Strobe speed 5 4 8 Dimming curve 6 4 9 Cut off dimming response 6 4 10 Dimming behaviour 6 4 11 LED frequency adjustment 6 4 12 LCD retro illumination 7 4 13 Software version and LED temperature 7 4 14 PRO BASIC 7 4 15 Reset 7 MAI...

Страница 3: ...operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The limitation extends to damages for personal injury property damage loss of operations loss of profits loss of product or loss of time whether incurred in by the customer the customer s employees or a third party Apart from the instructions given on this manual all relevant safety and h...

Страница 4: ...emperature of the LED is fixed at either warm 3200K theatre standard or cool 5600K which is becoming more common in TV studio applications and in theatres using colour filters Although regular colour filters may be used with an LED source the non continuous spectrum of the LED produces a different effect with many standard colours Lee Filters Rosco and other manufacturers supply colour filters spe...

Страница 5: ...s 4 1 DMX OR MANUAL Mode Select the LED control mode between DMX factory setting and manual To change the control mode press once the rotary selector until an arrow appears on the menu Turn the selector to the right or the left to select the desired mode of operation and press to confirm your selection Tap the rotary selector and the LCD screen will display the mode status and the current value 4 ...

Страница 6: ...en it is remotely controlled through DMX required DMXCfg function enabled Factory setting OPEN 3 8 16b 8 BITS PRESS THE ROTARY SELECTOR TO ACTIVATE 3 8 16b 8 BITS 3 8 16b 16 BITS TURN TO SELECT MANUAL OR DMX AND PRESS TO CONFIRM 4 DMXCfg OFF PRESS THE ROTARY SELECTOR TO ACTIVATE 4 DMXCfg OFF 4 DMXCfg ON TURN TO SELECT MANUAL OR DMX AND PRESS TO CONFIRM PRESS TO ACTIVATE THE MENU AN ARROW SHOULD AP...

Страница 7: ...as The frequency can be adjusted from a selection of 13th different values between 2KHz to 460Hz When DMXCfg function is enabled the frequency is controlled through the dedicated DMX channel and this menu becomes inactive Factory setting 2kHz PRESS TO ACTIVATE THE MENU AN ARROW SHOULD APPEAR 8 Curves LED_HALO REPRODUCE HALOGEN LAMP BEHAVIOUR 8 Curves LED_HALO 8 Curves LINEAR LINEAR DIMMING CONTROL...

Страница 8: ...MENT The fuse holder is fitted on the rear of the unit Type 6 3A 5x20mm 250 VAC DC fast blow fuse CAUTION Replace the fuse only when power is disconnected 6 CLEANING AND MAINTENANCE To ensure maximum performance of the product a regular maintenance service should be carried out Please make sure the product is cold and disconnected from power supply when doing this clean all reflective parts such a...

Страница 9: ... controlled through DMX DMXCfg function enable OPEN ON SPEED xx select value from 01 slowest to 10 fastest CLOSED OFF OPEN 8 Curves select the dimming curve LED HAL SQUARE LINEAR LED HAL 9 CutOff replicate the halogen lamp dimming behaviour at cut off FAST NOT ACTIVE SLOW ACTIVE SLOW 10 Smooth dimmere response OFF Immediate response SLOW 300ms FAST 150ms Smooth 11 Freq set the LED frequency This m...

Страница 10: ...80 Speed 81 100 Speed 101 120 Speed 121 140 Speed 141 160 Speed 161 180 Speed 181 200 Speed 201 220 Speed fast 221 240 Closed and reserved 241 255 Closed 4 Frequency 00 20 3 kHz available only if 21 40 2 4 kHz DMX Cfg ON 41 60 2 0 kHz OFF by deafault 61 80 1 7 kHz Note 81 100 1 5 kHz for technical reasons all frequencies may not be available on all products 141 160 1 1 kHz 161 180 939 Hz 181 200 7...

Страница 11: ...ben declaran bajo su responsabilidad que los productos aquì listados I sono conformi alle seguenti norme ed ai requisiti delle seguenti direttive CEE GB conform to the following standards and to the requirements of following EEC directives D den nachfolgend aufgeführten Normen und EEC Vorschriften entsprechen F sont conformes aux normes et prescriptions CEE ci aprés E cumplen de hecho con las sigu...

Страница 12: ...so Faulty product Defekte s Produkt Produit défectueux Producto defectuoso Descrizione del problema Problem found Beschreibung des Defekts Description du défaut Descripciòn del problema ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ ____...

Страница 13: ...Luci della Ribalta srl Via Berna 14 46042 Castel Goffredo mn Italy tel 39 0376 771 777 fax 39 0376 772 140 email info ldr it ...

Отзывы: