Mounting procedure TCU
Ref : C3131320010
Version : A1
Cable management in the TCU neighborhood.
Incorrect wiring will prevent the system from operating properly.
TCU has to be connected to +12V or +24V through 5A fuse protection.
TCU must be connected on Ignition (IGN).
When TCU and ECU or EBS are connected to a same CAN network,
they must share the
same ground.
LDL Technology can provide the wiring harness (see table below) :
Nota : This cable has a
minimum curvature radius about 80mm
.
Reference
Description
11 231 0000
Harness CAN (#1-Can)
11 232 0000
Harness (#1)
15 018 0000
Cable TCU CAN 1,2m - Wabco
15 017 0000
Cable TCU CAN 1,2m - EB+ gen3 - Haldex
15 016 0000
Cable TCU CAN Y 1,2m - EB+ gen2 - Haldex
15 015 0000
Cable TCU CAN 1,2m - EB+ gen2 - Haldex
15 014 0000
Cable TCU CAN 1,2m Deutsh 4 contacts 0462-201-16141 - Knorr
15 024 0000
Cable TCU CAN 1,2m – WABCO GIO5