INTRODUCTION

The ONE-PTT dynamic microphone adds more versatility to your ONE unit.This new

device allows you to have within your reach a public announcement input. 

This Push To Talk microphone can be directly connected to the priority audio input to

bypass the back ground music. As it is directly powered from the USB port inside the unit,
you do not need to add an external power supply.

With the included microphone stand, you can hang this microphone to the ONE 500

side   for   a   fast   and   easy   call.   You   can   also   fix   it   to   any  other   surface   following   your
preferences.

DESCRIPTION

This accesory is designed to use in ONE systems, it includes an audio preamp board

and all the accessories needed to install it. 

The   preamp   board   takes   power   from   the   ONE   USB   port.   It   includes   a   quality

preamplifier with a gain of 40dB to convert the microphone level to an output line level
compatible with 1Vrms inputs. The included circuit also converts the push to talk signal to
a contact output, that is already prepared to be connected in the PRIO audio inputs 1 or 2. 

CONFIGURATION

Connections should be made according to the quick guide located in the last page of

this manual, no further configuration is needed. With the ONE default configuration, if you
press the PTT microphone,   the audio will be routed to all zones. You can change the
corresponding input settings in the PA Matrix screen menu. 

Additional advanced configuration could be applied to adapt the PTT to your needs.

For example:

Enable the use of the PTT when the system is in emergency (VA) state: Enter In

advance   settings   by   pressing   ACK+OK   for   3   seconds.   Modify   the   variable   called
“DAM_PA_SRC_IN_VA_CUT_THRESHOLD” by selecting ID:2299 (FW v2.0.0.2). Change
the value to 3 and input1 will be available to be used in VA state according to the system
inputs priorities. 

A similar process must be done to allow the PTT if the AC power is not active (battery

mode): Enter In advance settings by pressing ACK+OK for 3 seconds. Modify the variable
called   “DAM_PA_SRC_IN_BATT_CUT_THRESHOLD”  by   selecting   ID:229A   (FW
v2.0.0.2). Change the value to 3 and input1 will be available to be used in battery mode
according to the system inputs priorities. 

3

Figure 1: Examples of PTT placement in a  system.