background image

User Manual: Rack mounting accesory19”ONE-500

 

ONE-RMA

8

Prepare the ONE-500 unit for installation 
on the ONE-RMA support:
1. Make sure that the front of the 
equipment is correctly oriented (see user 
manual ONE-500)
2. Remove the 2 bolts from the lower 
front corners of ONE-500

Place the ONE-500 unit on the ONE-
RMA support by putting the back side of 
the equipment so that the vertical tabs of 
the back piece (B) coincide with the slots 
on the ONE-500 base.

Put the ONE-500 equipment on the 
ONE-RMA support and fix them using the
supplied bolts

9

Push the assembled equipment until both
latches click.

5

Содержание ONE-500

Страница 1: ...User manual Rack mounting accesory19 ONE 500 ONE RMA ...

Страница 2: ...Index 1INTRODUCTION 1 1 1General description 1 2INSTALLATION 2 3TECHNICAL CHARACTERISTICS 4 ...

Страница 3: ...iring of the system and its subsequent maintenance The mounting kit ONE RMA has two high strength steel guides that allow the unit to be completely removed from the rack without the need to disassemble the ONE 500 unit It has lock handles that allow the ONE 500 unit to be integrated with the rest of the equipment in the rack cabinet 1 1 General description Id Description Cantidad F Front 1 B Back ...

Страница 4: ...2 ...

Страница 5: ...ear piece B is visible Attach the back piece to the side pieces L and R using 2 M3 bolts B3 3 Screw the rear supports Rs using 4 M6 bolts B6 into the rear posts of the rack The general installation height of the ONE RMA support is determined by the lower bolt of the rear supports that coincides in height with the position of the lower bolt on the front of the support 4 Introduce the preassembly of...

Страница 6: ... of the support ONE RMA to the rack using 4 M6 bolts B6 and 4 nylon packing rings M6 W6 Remember the lower bolt must coincide with the step 4 height 7 Extend the support to access the sides from inside Through the slots bolt the sides L and R to two holes with threads of the rear supports Rs using 4 M4 B4 bolts 4 ...

Страница 7: ...anual ONE 500 2 Remove the 2 bolts from the lower front corners of ONE 500 Place the ONE 500 unit on the ONE RMA support by putting the back side of the equipment so that the vertical tabs of the back piece B coincide with the slots on the ONE 500 base Put the ONE 500 equipment on the ONE RMA support and fix them using the supplied bolts 9 Push the assembled equipment until both latches click 5 ...

Страница 8: ...odel ONE RMA Material Fe Color Black RAL9005 Size 3U 19 rack Extendable bottom racks from 500 to 900mm Tray extension 550 mm 21 6 Paching size 490 x 420 x 50 mm 19 3 x 16 5 x 2 Net weight 3 6 Kg 7 9 lb Total weight 3 9 Kg 8 6 lb 6 ...

Страница 9: ......

Отзывы: