Copyright © 2020 LCJ CAPTEURS
19
15 CV7SF2
15.1
CONTENT OF DELIVERY
15.2
INSTALLATION
The CV7SF2 wind sensor is designed for outdoor operation,
exposed to natural light. It must be installed in an area free
from any air flow perturbation. Choose a location free from
any obstacle and situated at least 150 cm from the ground.
The maximum radio signal range is 200 meters. Best results
are obtained in a 50 meters distance between the sensor
and its receiver. The signal can be perturbated by materials
such as carbon, aluminium, steel...
A minimum distance of 10 meters between the arm and any
conductive material is recommended.
Specific environments may cause bad reception. Please
contact our technical support in that case.
15.3
SENSOR ALIGNMENT
A mark below the sensor indicates the alignment. The
vertical bracket is designed for mounting on a horizontal
surface, usually the mast head on a sailing boat. For
mounting on the side of the mast, an additional bracket is
available separately (see section 12.2). The CV7SF2
sensor must be installed with the
“Nord” mark on the
bracket aligned to the geographical North for a fix
installation on shore. Use a compass, taking the deviation
in account.
15.4
CONNECTIONS
Open the receiver to access the connection terminal. The
NMEA0183 data output is connected as shown below:
15.5
DIMENSIONS
User manual
Receiver
CV7SF2
wireless sensor
with vertical arm
The CV7SF2 is compliant with the Directive 1999/5/CE "R&TTE"