background image

 

Copyright © 2020 LCJ CAPTEURS

 

CV7 manual 2020 / English

 

1

 

 

 

 

 

 

 

USER MANUAL  

 

 

CV7 

 

CV7 Standard 

CV7-V 

 CV7-C 

CV7SF2 

 

 

LCJ CAPTEURS 
29 Allée des Cinq Continents 
ZA le Chêne Ferré 
44120 VERTOU – France 
Tél : 33(0)2 40 05 08 55 
Email [email protected] 
www.lcjcapteurs.com 
SIRET : 42493307500022 / RCS Nantes 
VAT : FR17424933075 

             EN 55022  EN55024 

Содержание CV7

Страница 1: ... MANUAL CV7 CV7 Standard CV7 V CV7 C CV7SF2 LCJ CAPTEURS 29 Allée des Cinq Continents ZA le Chêne Ferré 44120 VERTOU France Tél 33 0 2 40 05 08 55 Email info lcjcapteurs com www lcjcapteurs com SIRET 42493307500022 RCS Nantes VAT FR17424933075 EN 55022 EN55024 ...

Страница 2: ... C 8 5 1 CONTENT OF DELIVERY 8 5 2 SENSOR ALIGNMENT 8 5 3 DIMENSIONS 8 6 WINDYPLUG 9 6 1 TYPICAL INSTALLATION OVERVIEW 9 6 2 RECOMMENDATIONS 9 6 3 INSTALLATION 9 6 4 CONNECTIONS 9 6 5 DATA SOURCES 9 6 6 TECHNICAL SPECIFICATIONS 9 7 OPTION CANBUS RM 10 7 1 TYPICAL INSTALLATION OVERVIEW 10 7 2 CONNECTIONS 10 7 3 INTERFACE 10 7 4 COMMISSIONING 10 7 5 CALIBRATING THE MAST ANGLE SENSOR MID SHIP AND MAS...

Страница 3: ... SILVA and FI30 13 9 1 DIMENSIONS 13 10 OPTION BARO 13 10 1 DIMENSIONS 13 11 OPTION USB 14 11 1 CONNECTIONS 14 11 2 SPECIFICATIONS 14 12 MOUNT ADAPTERS 14 12 1 1 ADAPTOR 14 12 2 MOUNT ON VERTICAL SURFACE 14 13 SPECIFICATIONS 15 14 ADDENDUM 16 14 1 NMEA0183 AND NMEA2000 INTERFACES 16 14 2 MOUNTING TEMPLATE 17 15 CV7SF2 19 15 1 CONTENT OF DELIVERY 19 15 2 INSTALLATION 19 15 3 SENSOR ALIGNMENT 19 15 ...

Страница 4: ...turned to the manufacturer Do not mix electronic disposal with domestic or industrial refuse 1 4 USE OF THIS MANUAL This manual serves as a guideline for the safe and effective installation operation and maintenance of the Ultrasonic Wind Sensors of the CV7 range from LCJ Capteurs It is recommended to follow carefully the instructions contained herein Keep this manual in a safe place 1 5 VALIDITY ...

Страница 5: ...must be installed with the Nord mark on the bracket aligned to the geographical North for a fixed installation on shore and to the bow on a vessel Fine alignment can be performed with the application configuration CV7 available upon request 2 3 CONNECTIONS Red wire Power Blue wire Power Yellow wire NMEA TX Green wire NMEA RX Connect to 12 V power supply 8 33 VDC Connect the yellow and green wires ...

Страница 6: ...SENSOR ALIGNMENT CV7 sensor view from below 3 3 DIMENSIONS The oblique bracket is meant to be mounted on a horizontal surface It is usually fixed on the mast head of a sailing boat The oblique arm is toward the bow CV7 with oblique pole 25 m cable User manual Oblique bracket ...

Страница 7: ... on a horizontal surface usually the mast head on a sailing boat To be mounted on the side of the mast an additional bracket is available separately see section 12 2 The CV7 V sensor must be installed with the Nord mark on the bracket aligned to the geographical North for a fixed installation on shore 4 3 DIMENSIONS CV7 sensor with vertical pole 25 m cable User manual Bracket ...

Страница 8: ...e usually the mast head on a sailing boat For mounting on the side of the mast an additional bracket is available separately see section 12 2 The CV7 C sensor must be installed with the Nord mark on the bracket aligned to the geographical North for a fixed installation on shore 5 3 DIMENSIONS Weight 200 gr sensor pole bracket CV7 sensor with vertical carbon arm 25 m cable User manual Bracket 760 m...

Страница 9: ... cap and slide the 4 wires through it one after another and then the cable s cover Insert the wire terminals into the connectors colour for colour Just push them and they will be trapped in place Blue 0V power supply Red 12V power supply Green NMEA Yellow NMEA Push the protective cap back in place The hole in the cap must be aligned to the LED indicator Once the CV7 connection is completed you can...

Страница 10: ...tification of the potentiometer s polarity port starboard values Position 5 mid ship Place mast in mid ship position and set the angle to 0 Position 4 port end Place the mast in port end position like sailing starboard and set the angle to the relevant value theoretical or measured Position 3 starboard end Place the mast in starboard end position like sailing port side and set the angle to the rel...

Страница 11: ... COMMISSIONING Once you have completed your connections refer to the Raymarine manual for sensor alignment using the function provided by your display With the STBG option you also have access to all your usual functions To align the masthead you can press B 1 and B 1 8 1 3 APPLICATION After selecting the coding switches 1 2 3 or 4 depending on your display and configuring the sensor alignment the...

Страница 12: ...MISSIONING Once you have completed your connections refer to the B G manual for sensor alignment using the function provided by your display With the STBG option you also have access to all your usual functions To align the masthead you can press B 1 and B 1 8 2 3 APPLICATION After selecting the coding switches 1 2 3 or 4 depending on your display and configuring the sensor alignment the power mus...

Страница 13: ...to the serial port of a PC and use our configuration software 9 1 DIMENSIONS Dimensions 131 x 58 x 37 mm 10 OPTION BARO The BARO OPTION is a junction box that adds the atmospheric pressure to the NMEA0183 CV7 data Connect as follow 10 1 DIMENSIONS Dimensions 68 x 58 x 22 mm NMEA OUT NMEA OUT 0V NMEA CV7 Green CV7 Yellow CV7 Blue CV7 Red 0V 12 VDC ...

Страница 14: ...on of the website www lcjcapteurs com It is an executable file Double click on the file to launch the installation Once the CV7 is connected to the USB port your relevant software will immediately identify the NMEA0183 sentences via an emulated COM port 11 2 SPECIFICATIONS Dimensions 57 x 43 x 24 mm Weight 20 g without cable and connector Cable length 1 50 m Standard USB type A connector Screw ter...

Страница 15: ... 9 5 mA 9 5 mA 9 5 mA autonomous for transmitter 5 8 mA for receiver Operating temperature range without iceing 15 C 55 C 15 C 55 C 15 C 55 C 10 C 55 C Connection line 25 m of cable 4 x 0 22 mm2 25 m of cable 4 x 0 22 mm2 25 m of cable 4 x 0 22 mm2 Radio transmitter 433 mHz Tx power 10 dbm Message time 25 ms Interconnection Direct 12 V 0 V NMEA NMEA Direct 12 V 0 V NMEA NMEA Direct 12 V 0 V NMEA N...

Страница 16: ... N knots Wind speed Reference Wind direction in degrees Wind temperature sentence WIXDR C 022 0 C 52 CheckSum Unit C Value with one decimal Sentences added by the Baro3 option IIVWR 014 0 R 02 40 N 01 23 M 004 44 K 7E WIMDA I 1 0200 B 021 5 C Sentences for LCJ CAPTEURS technical use only PLCJ AAAA BBBB CC DDDD EEEE PLCJEFFFF GGGG HHHH IIII JJ Logging 2 minutes of NMEA sentences flow allows making ...

Страница 17: ...Copyright 2020 LCJ CAPTEURS 17 14 2 MOUNTING TEMPLATE WARNING Check the scale when printing this document Measure indications are in millimetres Vertical bracket ...

Страница 18: ...18 Copyright 2020 LCJ CAPTEURS Oblique bracket ...

Страница 19: ... Specific environments may cause bad reception Please contact our technical support in that case 15 3 SENSOR ALIGNMENT A mark below the sensor indicates the alignment The vertical bracket is designed for mounting on a horizontal surface usually the mast head on a sailing boat For mounting on the side of the mast an additional bracket is available separately see section 12 2 The CV7SF2 sensor must ...

Отзывы: