Checking Tank Level

Callout

Fig. 6 Descriptions

A

Battery life of sensor

B

Signal strength between app and sensor

C

Quality of sensor’s measurement

A. 

The app will report when the tank is empty (

Fig.5

).

Fig.3 

 A

B

Operation

B. 

The app will report to the user the battery life of the 

sensor, communication signal strength between the 

app and the sensor, and other features for the user’s 

convenience (

Fig.6 and 7

).

 C

Fig.4 

Fig.5 

Rubber Pad

Magnets

Place sensor here

6. 

Place the magnetic sensor on underside of the tank in 

the center. Tank removal may or may not be necessary 

depending on accessibility to the bottom (underside) of the 

tank (

Fig.4

).

Fig.6 

NOTE: 

If the BottleCheck is removed or repositioned 

multiple times, it may be necessary to apply more sonic 

grease.

7. 

Once the sensor is placed and the fluid has settled, the 

app will display a reading.

NOTE: 

If the tank was flipped during the application of the 

sensor, the LPG fluid will be sloshing around in the tank for 

a few minutes and the quality of the measurements will be 

reduced until this has stabilized.

8. 

If tank was removed for the application of the sensor, 

safely return tank back to its original location.

4. 

Once the app and sensor are paired, wipe off the bottom 

of the tank where the sensor will be magnetically mounted.

5. 

Apply the provided Sonic Grease directly to the rubber 

pad on the center of the sensor before attaching to the 

tank (

Fig.3

).

Содержание Lippert BottleCheck

Страница 1: ...placement 5 Resources Required 5 Troubleshooting 6 Leveling and Zeroing 6 Notes 7 Local Distributor Information 8 Australia 8 New South Wales Head Office Trade Clients Only 8 New Zealand 8 Auckland Tr...

Страница 2: ...CONCENTRATIONS DUE TO EXPLOSION HAZARD THE WARNING SYMBOL ABOVE IS A SIGN THAT A PROCEDURE HAS A SAFETY RISK INVOLVED AND MAY CAUSE DEATH SERIOUS PERSONAL INJURY OR SEVERE PRODUCT AND OR PROPERTY DAMA...

Страница 3: ...BottleCheck sensor may require pressing the SYNC button 5 times in a row in order to wake up the sensor Fig 2 A Fig 1 Installation NOTE Part numbers are shown for identification purposes only NOTE Spa...

Страница 4: ...y or may not be necessary depending on accessibility to the bottom underside of the tank Fig 4 Fig 6 NOTE If the BottleCheck is removed or repositioned multiple times it may be necessary to apply more...

Страница 5: ...ween the lid and the base Fig 8 3 Pry outward to begin releasing the lid from the base Continue prying at each alignment mark location until the two halves separate Fig 9 Fig 9 Resources Required CR20...

Страница 6: ...el has not settled in LP tank If tank has been moved wait for fuel to settle Sensor improperly placed on LP tank Be sure sensor is properly installed on LP tank see Installation section Poor connectio...

Страница 7: ...and app bubble leveling is helpful and may be necessary it is only critically essential for extremely large vessels over 45 kg Fig 13 Manual information may be distributed as a complete document only...

Страница 8: ...Monday to Friday Public holidays excluded Queensland Coast to Coast RV Services 48 56 Meakin Road Meadowbrook QLD 4131 Phone 07 3386 7100 Fax 07 3386 7199 Email salesqld coastrv com au Western Austra...

Отзывы: