LCI Floe 636 Скачать руководство пользователя страница 1

1

lci1.com      

 

574-537-8900    

 

Rev: 11.05.20

Floë 636 Integrated 

Water Drainage System

Installation and Owner’s Manual

(For Aftermarket Applications)

CCD-0003522

Table of Contents

Introduction

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

1

Safety

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Resources Required

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Parts List

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Installation Of Model 636

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Preparation

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

2

Attach Box To Wall

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

3

Connect Tee Fittings And Air Line

    . . . . . . . . . . . . . . . . . . . . .  

3

Connect To 12V DC Power Supply

    . . . . . . . . . . . . . . . . . . . .  

4

Test For Air Leaks

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

4

Operation

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

5

What Is Floë

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

5

Importance Of A Sealed System For Draining

    . . . . . . . . .  

5

General Guidelines For Model 636

    . . . . . . . . . . . . . . . . . . . .  

6

Model 636 Operation

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

6

RV Water System Diagram

    . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

7

Troubleshooting

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

8

Floë

 636

Induratec

 

Integrated 

12V DC Water 

Drainage System

Installation and 

Owner’s Manual

(For Aftermarket Applications)

Floë Water Drainage Kit

Floë Water Drainage Kit

Part #

Part #

Description

Description

809127

Model 636 12V DC water drainage system

Introduction

Floë is a water drainage device that will remove residual 

water trapped in water supply systems in RVs, marine 

vessels and mobile vehicles with a 12V DC electrical 

system. This will prevent the pipes from freezing in the 

winter and also flush out stale water in the summer. 

Additionally, it will remove dirt and lime scale from hot 

water heaters. 
Additional information about this product can be obtained 

from 

lci1.com/support

 or by using the myLCI app. 

Replacement kits can be ordered fro

https://store.lci1.

com

 or by using the myLCI app.

The myLCI app is available for free on iTunes

®

 for iPhone

®

 

and iPad

®

 and also on Google Play

 for Android

 users.

iTunes

®

, iPhone

®

, and iPad

®

 are registered trademarks of 

Apple Inc.
Google Play

 and Android

 are trademarks of Google Inc.

Содержание Floe 636

Страница 1: ...rainage Kit Flo Water Drainage Kit Part Part Description Description 809127 Model 636 12V DC water drainage system Introduction Flo is a water drainage device that will remove residual water trapped i...

Страница 2: ...R PROPERTY DAMAGE IF NOT PERFORMED SAFELY WITHIN THE PARAMETERS SET FORTH IN THIS MANUAL Model 636 Model 636 Description Description Qty Qty Flo Induratec 636 1 Air line 13 1 CTS one way double valve...

Страница 3: ...nstall the Flo unit on an outside wall since it could create bumps on the outside finish of RVs NOTE Flo should be installed upright not flat Try to use a corner door jamb or cupboard to keep Flo stra...

Страница 4: ...of the tee should extend toward the tank while the shorter side should extend toward the pump Figs 6 7 NOTE If larger or smaller pipes are used adapters can be purchased from hardware stores Addition...

Страница 5: ...er or the need for antifreeze in the fresh water system in the winter Two complete draindowns are recommended initially to identify any individual outlets that may require draining a second time Diffe...

Страница 6: ...perational procedures 1 Manually drain water tanks and water heater and close dump valves for all 2 Set valves to bypass water heater as if using antifreeze for the system 3 Close all faucets and outl...

Страница 7: ...resh air is a good sterilizer Showers or faucets may have mixer valves and therefore two pipes leading to them both hot and cold Remember to leave in the open position but leave it set to the middle b...

Страница 8: ...ctor Move to the end of the air line where it enters the main water valve tee and remove air line from tee Hold thumb over end of air line and switch Flo on If Flo stops the joints are good leading ba...