LCI Floe 636 Скачать руководство пользователя страница 4

4

lci1.com      

 

574-537-8900    

 

Rev: 11.05.20

Floë 636 Integrated 

Water Drainage System

Installation and Owner’s Manual

(For Aftermarket Applications)

CCD-0003522

Connect To 12V DC Power Supply

1. 

The supplied 13’ DC wire has male and female 

connectors and a fuse 

(Fig.8)

. Connect one end of the 

connector to the Floë box and the other end to a power 

supply.

NOTE: 

The white connector can also be removed to create 

bare wires on the end. Then it can be fitted to a fuse box or 

fitted directly to the battery using ring terminals.

NOTE: 

The fused wire is for a red/positive connection and 

can also be fitted onto an optional in-line switch included 

with the kit 

(Fig.8)

.

2. 

The 15A power plug can be fitted to a cigar/cigarette 

lighter socket 

(Fig.8)

. Connect one end to the connector on 

the Floë box and the other end to a socket.

3. 

Use a cable tie to hold together excess cord.

 

Tank 

Faucet 

Fig.5 

Fig.6 

Fig.7 

13’ DC Wire

power plug

in-line switch

short side

to pump

long side

to tank

Fig.8 

NOTE: 

Use a cloth to mop up excess water from the cut 

water line.

3. 

Insert teeth end of the barbed connector onto the end of 

the hose 

(Fig.5)

.

4. 

Slide hose clamp over end and tighten 

(Fig.5)

5. 

Repeat process for other side of the cut hose.

6. 

Fit the ends of the 

1/2

” air line tee firmly into the 

connectors, utilizing the tee’s push-fit connections 

(Fig.6)

The long side of the tee should extend toward the tank while 

the shorter side should extend toward the pump 

(Figs.6, 7)

.

NOTE: 

If larger or smaller pipes are used, adapters can 

be purchased from hardware stores. Additionally, the tee 

can also be fitted to rigid plastic and copper pipes without 

adding barbed connectors.

NOTE: 

There are two one-way valves built into the tee. 

One is to stop water escaping back up into the Floë unit. 

The other is to stop air traveling back into the water tank, 

where it would escape out of the tank air vent.

7. 

Measure the distance from the air line shutoff valve on 

the Floë box to the tee installed on the water line.

8. 

Cut air line to length, leaving at least an extra half inch to 

an inch of air line to slide into the connectors.

Test For Air Leaks

At this point Floë has been dry fit. Test that all joints 

leading up to the main water line are fitted correctly without 

air leaks. Locate the main water line tee and remove the 

barbed connector from the short end of the tee leading 

to the faucets, NOT the water tank long end. The barbed 

connector is removed by pulling back on the collar of the 

tee that holds the barbs in place.
Place a finger into the tee to seal this end and switch on 

Floë. Floë should be tricked into stopping at 15 psi. If Floë 

stops, then the joints leading to the water system are fine. 

If Floë doesn’t stop, then remove, wet and reseat the air 

line into the connectors leading back to Floë. It is essential 

there is a good seal on the open end of the tee to allow this 

test to work.

To Tank

To Pump

Содержание Floe 636

Страница 1: ...rainage Kit Flo Water Drainage Kit Part Part Description Description 809127 Model 636 12V DC water drainage system Introduction Flo is a water drainage device that will remove residual water trapped i...

Страница 2: ...R PROPERTY DAMAGE IF NOT PERFORMED SAFELY WITHIN THE PARAMETERS SET FORTH IN THIS MANUAL Model 636 Model 636 Description Description Qty Qty Flo Induratec 636 1 Air line 13 1 CTS one way double valve...

Страница 3: ...nstall the Flo unit on an outside wall since it could create bumps on the outside finish of RVs NOTE Flo should be installed upright not flat Try to use a corner door jamb or cupboard to keep Flo stra...

Страница 4: ...of the tee should extend toward the tank while the shorter side should extend toward the pump Figs 6 7 NOTE If larger or smaller pipes are used adapters can be purchased from hardware stores Addition...

Страница 5: ...er or the need for antifreeze in the fresh water system in the winter Two complete draindowns are recommended initially to identify any individual outlets that may require draining a second time Diffe...

Страница 6: ...perational procedures 1 Manually drain water tanks and water heater and close dump valves for all 2 Set valves to bypass water heater as if using antifreeze for the system 3 Close all faucets and outl...

Страница 7: ...resh air is a good sterilizer Showers or faucets may have mixer valves and therefore two pipes leading to them both hot and cold Remember to leave in the open position but leave it set to the middle b...

Страница 8: ...ctor Move to the end of the air line where it enters the main water valve tee and remove air line from tee Hold thumb over end of air line and switch Flo on If Flo stops the joints are good leading ba...