UV BAR18
www.lc-group.ca
- - 7 - -
7. DMX-512 controller connection
3pins XLR signal output connector
3pins XLR signal input connector
(female)
(male)
1: earth
2 : signal -
3 :
8. DMX address setting
Set an address for each light, and accept the DMX signal from DMX controller, as per the
demand, user can set the same address for all lights, or different address for different light.
If set several light with the same DMX starting address, all lights will accept the same DMX
signal from DMX controller and work synchronously.
If set different address for each light, the light will accept signal from the DMX controller as per
the DMX starting address, if use this way, user must set the DMX starting address for the light
according to channel quantity of each light.
This light has 2 DMX modes: 2/20 channels, when use 2-channel mode, the 1st light has starting
address 1, the 2
nd
light has starting address 3 (1*2+1), the 3
rd
light has starting address 5 (2*2+1),...;
when use 20channel mode, the 1
st
light has starting address 1, the 2
nd
light has starting address
21(1*20+1), the 3
rd
light has starting address 41 (2*20+1).