background image

     

 

SP Range User Guide v7 June 2020 

Installation & User Guide  

SP Range 

6.0

 

Installation 

5.1 Non-DCS Model

 

The non-DCS model SP battery does not include an internal DC-DC charger. As illustrated in Figure 2, 

it can be charged via the red positive (

+ Fused

) and black negative (

-

) terminals from an: 

-

 

External AC charger source; 

-

 

External solar charger source; or 

-

 

External DC-DC charger source. 

 

Figure 2 

 Battery Charging Terminal Connections 

The procedure of installing the SP battery (with no internal DC-DC charger) is as follows: 

1)

 

Before making any electrical connections to or from the battery, first secure the battery in 

place, preferably with the fit for purpose LBS mounting bracket kit, or using suitable straps. 

2)

 

Once the battery is securely in place, unscrew the plastic terminal caps from the  fused red 

positive (

+ Fused

) and black negative (

-

) terminals.  

a.

 

Do  not  lose  or  discard the  plastic  terminal  caps  as  they  are  required  at  the  end  of 

installation. 

b.

 

With exposed positive (

+ Fused

) and negative (

-

) terminals the battery is susceptible 

to short circuit if a metallic object such as a spanner or wrench accidentally dropped 

onto both terminals at the same time, causing sparks and potential damage to the 

battery. 

3)

 

Using a spanner or adjustable wrench, remove the metal nut and flat washer on each terminal. 

The  nut  will  be  re-used  to  ensure  a  tight  connection  following  connection  of  the  charging 

source and loads. Do not remove the MEGA fuse between the two 

+

 terminals. 

4)

 

Ensure the charging source positive (

+

) and negative (

-

) has M8 ring terminals suitable sized 

to match the battery M8 terminals. 

5)

 

Connect all the charging and load cables to the battery fused positive (

+ Fused

) terminal. 

Place the flat washer on top and then fasten the nut tight (or max 8Nm if you have a torque 

Negative (

-

)

 

Fused 

positive (

+

)

 

Содержание LBS-12110-SP

Страница 1: ... Standard Power SP Range Models LBS 12110 SP LBS 12110 SP DCS LBS 12150C SP LBS 12150C SP DCS LBS 12150C SP FT LBS 12150C SP DCS FT LBS 12150 SP LBS 12150 SP DCS LBS 12225 SP LBS 12225 SP DCS LBS 12300 SP LBS 12300 SP DCS v2 ...

Страница 2: ...nclosure 4 2 3 Maintain an acceptable temperature range 4 2 4 Avoid repeated shock and vibration 5 2 5 Avoid exposure to water or salt spray 5 2 6 Do not short circuit the battery 5 2 7 Mounting orientation 5 4 0 Longevity Depth of Discharge 6 5 0 Battery Management System 7 6 0 Installation 8 5 1 Non DCS Model 8 5 2 DCS Model 9 7 0 User Guide 11 8 0 Specifications 12 9 0 Care and Maintenance 13 1...

Страница 3: ...Alternating Current BMS Battery Management System DC Direct Current DoD Depth of Discharge HP High Power LBS Lithium Battery Systems LED Light Emitting Diode LFP Lithium Iron Phosphate LVD Low Voltage Disconnect RV Recreational Vehicle SoC State of Charge SP Standard Power V Voltage Voc Voltage Open Circuit VSR Volt Sensing Relay ...

Страница 4: ...ntinuous current and can therefore be used in higher power applications This User Guide covers the following SP 12V battery range LBS 12110 SP LBS 12110 SP DCS LBS 12150C SP LBS 12150C SP DCS LBS 12150C SP FT LBS 12150C SP FT DCS LBS 12150 SP LBS 12150 SP DCS LBS 12225 SP LBS 12225 SP DCS LBS 12300 SP LBS 12300 SP DCS As with all batteries you should consider the mechanical and environmental condi...

Страница 5: ...ry 2 2 Do not penetrate the battery enclosure You may be tempted to drill into the aluminium enclosure to secure mounting brackets Doing so may inadvertently penetrate one of the cells which could cause thermal runaway and vapour emissions Do not under any circumstances drill or penetrate into the enclosure Use only existing mounting holes in the battery and short screw lengths no greater than 13m...

Страница 6: ...otected hatch or compartment 2 6 Do not short circuit the battery Whilst the BMS will protect the internal cells from short circuit it is highly recommended to avoid short circuiting the battery The MEGA Fuse on the external positive terminal of the battery also provides over current protection if voltage is not present on the Fused terminal check for voltage on the Unfused terminal to check if th...

Страница 7: ...OD and then charging back to full again So DOD describes what percentage of the battery capacity is being used each time Note DOD is different to State of Charge SOC also known as Charge Level in fact they add together to 100 So 80 DOD equates to 20 SOC The less DOD you use each cycle the longer the battery will last This fact should be considered when choosing the battery Amp hour capacity You wi...

Страница 8: ...rotection Unlike lead acid batteries over charging or over discharging a lithium battery may lead to a hazardous scenario Therefore the BMS is the heart and soul of a lithium battery The Standard Power SP family BMS is a highly reliable solid state device which is primarily designed to keep the cells safe and the overall pack from being damaged by excessive voltage or excessive discharge event The...

Страница 9: ...ed red positive Fused and black negative terminals a Do not lose or discard the plastic terminal caps as they are required at the end of installation b With exposed positive Fused and negative terminals the battery is susceptible to short circuit if a metallic object such as a spanner or wrench accidentally dropped onto both terminals at the same time causing sparks and potential damage to the bat...

Страница 10: ...igure 3 DC DC Charging Terminal Connections The internal DC DC charger contains a status LED light and Voltage Sensing Relay VSR adjustment trim pot which indicates and adjusts at what input voltage from the vehicle alternator start battery the DC DC charger turns on and off There is a dead band of 0 5V so that it typically turns on at 13 3V and turns off at 12 8V Note that the voltage sensed by t...

Страница 11: ... with a 20A connection or you are connecting directly to the start battery then you can select the 20A charge setting on the battery Beware If you select 20A when connected via a standard cigarette socket you may blow the fuse connected to that circuit in your vehicle Direction Switch This switch provides the ability to reverse the DC charge direction Out so that the lithium battery can be used to...

Страница 12: ...ocker switch Please note unlike lead acid batteries lithium batteries hold their voltage over the cycle dropping off only when the battery is 90 discharged as indicated below for illustrative purposes Pay attention to this when assessing how full the battery is Once the voltage starts to approach 12V it is nearing empty and should be charged Some helpful hints 1 A normal full battery open circuit ...

Страница 13: ...SP Range User Guide v7 June 2020 Installation User Guide SP Range 12 8 0 Specifications ...

Страница 14: ...ultimately flatten it 2 If the battery is unintentionally discharged flat then it can be recovered First remove all loads sources and switch off the LED voltmeter Apply a dumb charger which charges the battery without needing to see the battery first 3 For long battery life keep it charged at above 13V at all times Check the battery once a month If the open circuit voltage has dropped to 13V or be...

Страница 15: ...eatedly then it will have a negative impact on longevity Maintaining the battery charge at 13V or higher will maintain good battery life Look after your lithium battery and it will give you many years of service Can the battery be recovered from flat Yes See Section 8 Does the battery capacity degrade over time Yes all batteries degrade slowly over time even with no load sources connected Storage ...

Страница 16: ... Us Head Office Manufacturing Address Unit 16 20 22 Ellerslie Road Meadowbrook QLD 4131 by appointment only Phone 1800 844 869 Office Hours 9am to 5pm Monday to Friday Email info lithiumbatterysystems com au Website www lithiumbatterysystems com au ABN 16 608 590 503 ACN 608 590 503 ...

Отзывы: