background image

    

___________________________________________________________________________ 
                                                               

Page 6                                                  User Guide LBS-1250-FPP_1.32

 

 

Battery User Guide 

V1.2 April 2018 

1.8 Level / State of Charge (SOC) 

To indicate the battery Level (aka State of Charge), use a pen or a key to 
depress  the  Level  button.  There  are  5  LEDs  representing  level  in 
increments of 20%: 

1)

 

0-20% (flashing if very low) 

2)

 

20-40% 

3)

 

40-60% 

4)

 

60-80% 

5)

 

80-100% 

 

The  LED’s  will  turn  off  after  5  seconds  to  minimise  internal  power 

consumption. 

 

 

1.9 On/Off, Init and Reset Buttons 

On/Off 

To turn the battery on slide the switch to the right. 
To turn the battery off slide the switch to the left. 
 

Reset Button 

The Reset button can be used to clear a fault, such as after the battery 
has discharged to empty and disconnected the loads to protect itself.  
 

Initialise Button 

The  Init  button  is  to  initialize  the  battery  for  the  first  time  during 
assembly, or if the battery has discharged below empty level and shut itself down completely. 
This would only happen if the battery is left empty for a long time.  
 

Alarm LED 

The Alarm LED flashes when an issue occurs; the number of flashes in sequence indicate what 
the issue is as below. There is also an audible buzzer. 
 

Permanent Fault 

Cell Under Voltage (battery empty) 

BMS (MOSFETs) too hot 

Battery too cold  

Battery too hot 

Short Circuit (Current > 1000A for 70µs) 

RESET 

LEDs 

OFF-ON 

INIT 

ALARM 
LEVEL 

RESET 

LEDs 

Содержание Freedom Power Pack LBS-1250-FPP-DCC

Страница 1: ...Battery User Guide Freedom Power Pack FPP 12V Portable Battery Camping Caravanning 4WD Fishing Emergency Power LBS 1250 FPP STD LBS 1250 FPP DCC POWERING FREEDOM ...

Страница 2: ...w to connect and operate the LBS 1250 FPP STD and LBS 1250 FPP DCC versions of the FPP As with all batteries you should consider the mechanical and environmental conditions that you intend to operate the battery in to maximise overall performance and achieve the longest battery life LBS offer these general guidelines however you should seek LBS advice or that of a qualified electrical tradesperson...

Страница 3: ...mbient temperature that the battery operates in is 60oC you should cease use immediately Operating outside of these guidelines diminishes the life and performance of the battery 3 Ensure the battery is not exposed to repeated shock and vibration Whilst the battery is robustly constructed it is not designed to operate continuously in high shock or high vibration environments 4 Ensure the battery is...

Страница 4: ...g with the battery in the OFF position If you are unsure how to install your battery seek advice from LBS or a suitably qualified 12V electrical tradesperson 6 Charging and discharging at the same time There are no issues with charging the battery and discharging the battery running loads at the same time The BMS counts the amps in and amps out and records the level state of charge ...

Страница 5: ...40 60 80 100 9 On Off Init Reset Buttons and Alarm 1 1 Battery Terminals The battery terminals are rated to the maximum capacity of the battery which is 100A for both the STD and DCC versions of the FPP High Power 200A version available on request The terminals can be used for either charge or load connections 1 2 Anderson Connectors The two grey Anderson connectors are rated to a maximum of 50A c...

Страница 6: ...le battery alternator Select the OUT position when using the battery to charge an external battery such as your vehicle starter battery Select the OFF position when not using the DC charger 1 4 USB Ports The FPP comes with two sets of dual USB ports 5V 1A and 2 1A These ports are outputs used for charging any device which uses a USB connection for charging Selecting the 2 1A USB port will charge f...

Страница 7: ...ff slide the switch to the left Reset Button The Reset button can be used to clear a fault such as after the battery has discharged to empty and disconnected the loads to protect itself Initialise Button The Init button is to initialize the battery for the first time during assembly or if the battery has discharged below empty level and shut itself down completely This would only happen if the bat...

Страница 8: ..._________________________ Page 7 User Guide LBS 1250 FPP_1 32 Battery User Guide V1 2 April 2018 7 Over Load Current 500A for 1 second 8 Over Current Current 100A for 10 seconds 9 Communications lost between Atmel and TI BQ microcontrollers both on BMS ...

Страница 9: ...20 40 60 80 100 For normal operation slide the OFF ON switch to the right and the SOC Level LEDs will light up for 5 seconds By depressing the Level button the battery will again light the LED s to indicate how full SOC the battery is The battery has an illuminated blue LBS logo which will glow when the battery is ON 2 1 FAQ What do I do if the battery does not seem to be operating Turn the batter...

Страница 10: ...cuit voltage of the solar panel may then be present at the loads which may provide up to 20V or more in sunlight for a 12V solar panel to any connected loads It is recommended to use regulated solar a solar panel with its own solar charge controller which can be connected as shown below 3 2 DC Source The FPP can be charged from a DC source such as a vehicle alternator start battery via the black A...

Страница 11: ... 3 3 Charging with an AC source The FPP can be charged by an AC battery charger via the terminals using alligator clips or one of the grey Anderson plugs 3 4 Reverse Charging through the DC Charger The Black DC Charger switch next to the black Anderson plug has the ability to reverse the direction of DC charging so that power goes FROM the FPP into the vehicle start battery to charge it up perhaps...

Страница 12: ...er battery too fast and overheat it Also be careful not to short the connections on either end together when connecting and disconnecting as both ends will be live 4 2 AC Loads If a DC to AC inverter is connected to the battery then AC loads can be powered An inverter of up to 600W can be connected via the grey Anderson plug An inverter of up to 1200W can be connected to the battery terminals Smal...

Страница 13: ...___________________________________________________________________________ Page 12 User Guide LBS 1250 FPP_1 32 Battery User Guide V1 2 April 2018 Battery Nameplates Specifications DCC STD ...

Страница 14: ..._____________ Page 13 User Guide LBS 1250 FPP_1 32 Battery User Guide V1 2 April 2018 CONTACTS Lithium Battery Systems Brisbane Australia National Sales Manager Chris Carrigan M 040 404 1189 E chris lithiumbatterysystems com au ABN 166 085 905 03 POWERING FREEDOM ...

Отзывы: