Defender Press Brake Guarding System Operation Manual
LS-CS-M-069
Page 40
Original Language Version: 1.04
Released:
01/04/2020
Note:
The Defender system will not allow a value to be entered which is outside of the
allowable range for that parameter. The valid range of values is displayed next to
the parameter’s name in the Parameter screen (ignore the units). If an attempt is
made to exceed the valid range, an
Entry out of range
message is displayed, and
the value will not be saved.
7.2
User Menu
The user menu does not have access control, and can be accessed by anyone.
7.2.1
Parameter 0
–
Buzzer On/Off
This parameter sets the behaviour of the buzzer.
•
ENABLED
. The buzzer will sound on every button press.
•
DISABLED
. The buzzer will never sound.
Use the ▲▼ buttons to navigate the options. Changes can be abandoned at any time by
pressing the
button. When the desired option has been selected, press the
ENTER
button,
the value will be written into the Defender’s non-volatile memory, and the system will return
to the parameter list.
7.3
Supervisor Menu
The Supervisor menu is password protected. When the
SUPERVISOR MENU
button is pressed,
the operator is prompted to enter the Supervisor level access code, as shown in
This is a numeric parameter as described in
Section 7.1.3
, and shown in
Note:
The factory default supervisor access code is 1111. This should be changed as
soon as the system is installed. If the Supervisor password is lost, contact Lazer
Safe Customer Support or your local supplier for assistance.
a
e
ENTER
0000
Enter access code
Figure 7-4: Supervisor Menu Access Screen
If an attempt to enter an access code fails, the message
Access code incorrect. Try again
is
displayed. There is no limit to the number of attempts that can be made.
7.3.1
Parameter 0
–
Supervisor Access Code
This parameter sets the value of the Supervisor level access code and can take any value
from 0000
– 9999.