LAWO vsm LBP Скачать руководство пользователя страница 6

6/23

Version: 4.0/1

vsm LCD Button Panels (LBP)

vsm LCD Button Panels User Manual

Introduction

3.

The 

vsm LCD Button Panels (LBP)

 are remote panels specifically designed for use  with 

vsmStudio

. The panels

can be configured  to  meet  every  production  environment’s  requirement.  A  Single  Destination,  a  Multiple
Destination, a XY configuration or a combination of those alternatives is possible. The hardware panels provide
multiple pages like the virtual panels. With the vsmStudio panel editor, LBP panels can be configured online or
offline where online changes will be displayed in real-time. 

The panels are connected to the vsmStudio control system via TCP/IP. The function possibilities of the  LBP-
series are manifold, for example they can perform routing, control devices -  or  signal  parameters.  Secondary
functions enable multiple actions at one button push. With the aid of the panel editor of the vsmStudio software
several panels can virtually be combined to one big  panel.  These  features  allow  the  implementation  of  every
operating  philosophy. 

Each LBP-button integrates a Liquid Crystal Display (LCD) with R/G/B backlight enabling the operator to arrange
any possible combination of functions, sources and targets across different pages. In addition to the Ethernet port
every LBP provides two GPIs and two GPOs and an RS422 port (RS422 for  external  accessories  only).  The
hardware panels are mounted into a solid steel coil coated housing and can be integrated into  every  production
environment. 

The LBP panels are available in a variety of different sizes and optionally for LBP-series only with one incremental
encoder instead of one LCD-button. Additionally, a 1RU incremental encoder stripe with 17 rotary encoders or an
RFID Tag Reader-box can be connected through the RS422 port of each LBP panel. All panels are to be powered
by an external capsulated 12Volts DC stabilized power supply with a maximum of 3% Voltage discrepancy, a
minimum current capability of 5A and external short-circuit-protection (fuse, circuit breaker or  electronic  short
circuit-protection within the power supply).

Key Features:

·

Every LBP without an incremental encoder is also available as a vsmSnap panel and can be used as  a
standalone fall-back panel. The vsmSnap panel stores a configuration and enables router control without
the need of any other controller hardware.

·

Software configurable buttons

·

Each button capable of performing single or multiple functions simultaneously

·

Each  panel  can  be  configured  as  “single  destination”,  “multiple  destinations”,  “XY”  panel  or  any
combination of these variations

·

Every LBP has two low power GPIs and GPOs

·

For LBP, an optional incremental encoder can be added for e.g. parameter entry

·

Every LBP is equipped with Ethernet interface

·

Button functions include: select sources or targets, GPI control, parameter control, macros, go-to, take,
lock, enable, escape, shift and many more

·

Every LBP enables offline and  online  configuration.  All  online  changes  occur  in  ‘real-time’  which
eliminates downtime

·

Every LBP without incremental encoder provides the option of being used as a “stand-alone” or “fall-back”
panel to directly control a router without any router control system (SNAP-panel)

·

One optional 1RU encoder-stripe with 17 incremental rotary encoders can be connected directly to each
LBP via RS422, if no RFID Tag reader is used

·

An optional RFID Tag Reader-box can be connected to each LBP through RS422 for access control, if no
1RU encoder-stripe is used

·

Full colour R/G/B backlight at the LBP’s allows the choice of multiple colours for button illumination.

Содержание vsm LBP

Страница 1: ...all product names products trademarks requisitions regulations guidelines specifications and norms are free from trade mark rights of third parties All entries in this document have been thoroughly ch...

Страница 2: ...3 Introduction 6 4 Overview 7 E3 Buttons 7 4 1 NKK Buttons 12 4 2 LBP Accessories 13 4 3 5 Operating Conditions 14 6 Preparing Panels for Operation 15 7 Preparing Accessories for Operation 16 8 Techni...

Страница 3: ...figuration and administration tool plus other software components vsmPanel vsmWebPanel vsmTimeSync etc vsm Gear User Manuals more about other hardware panel and interface options All Lawo manuals are...

Страница 4: ...rve the temperature range and humidity specified in the installation instructions Do NOT expose devices to liquids which may drip or splash Do NOT place objects filled with liquids such as vases upon...

Страница 5: ...tailed description of the fault We would like to remind you to please check carefully whether the failure is caused by erroneous configuration operation or connection before sending parts for repair P...

Страница 6: ...stripe with 17 rotary encoders or an RFID Tag Reader box can be connected through the RS422 port of each LBP panel All panels are to be powered by an external capsulated 12Volts DC stabilized power s...

Страница 7: ...ndensing humidity LBP 17 Number of buttons 17 LCD Buttons E3 R G B Backlight Options VSM SNAP Communication port 1xEthernet Dimensions 483mm x 43 7mm x 53 1mm WxHxD 1RU Weight approx 1 0KG Power Consu...

Страница 8: ...midity LBP 32 Number of buttons 32 LCD Buttons E3 R G B Backlight Options VSM SNAP Communication port 1xEthernet Dimensions 240mm x 111 5mm x 53mm WxHxD 2 5RU 2 Weight approx 1 0KG Power Consumption 6...

Страница 9: ...umidity LBP 34 Number of buttons 34 LCD Buttons E3 R G B Backlight Options VSM SNAP Communication port 1xEthernet Dimensions 483mm x 88mm x 53 2mm WxHxD 2RU Weight approx 1 4KG Power Consumption 6 5W...

Страница 10: ...Number of buttons 50 LCD Buttons E3 R G B Backlight 1 Encoder Options Communication port 1xEthernet Dimensions 483mm x 88mm x 68 3mm WxHxD 2RU Weight approx 1 7KG Power Consumption 8 5W 12VDC 0 71A ma...

Страница 11: ...g humidity LBP 39V vertical Number of buttons 39 LCD Buttons E3 R G B Backlight Options Communication port 1xEthernet Dimensions 92mm x 355 50mm x 59mm WxHxD Weight approx 1 3KG Power Consumption 7 2W...

Страница 12: ...sing humidity LBP 41e Number of buttons 42 LCD Buttons NKK R G B Backlight 1 Encoder Options Communication port 1xEthernet Dimensions 483mm x 43 7mm x 69 3mm WxHxD 1RU Weight approx 1 8KG Power Consum...

Страница 13: ...nel using RS422 via the RJ45 connectors on the rear of the LBP panel ENC 17 Number of Encoder 17 incremental encoder R G B Backlight Communication port RS422 communication to LBP panel only Dimensions...

Страница 14: ...alfunction of the whole device Spillage of any liquids e g coffee coke water onto into the device may cause damage The storage temperature of the device must be within 20 C to 60 C with a maximum of 7...

Страница 15: ...our administrator for static network settings and edit the Network section if required Do the following settings in VSM Discover Press Apply button in vsmDiscover if you are sure you have entered the...

Страница 16: ...he corresponding LBP panel to enable this feature A software reset is necessary for proper working external serial interface A powered and connected ENC 17 device will pulse blue on each encoder once...

Страница 17: ...internal I O voltage OK 5 Orange Blinks physical LAN connection TCP IP data transfer 8 1 2 ENC 17 Rear view 1 Orange Blinks receiving data from LBP panel 2 Yellow Blinks transmitting data to LBP pane...

Страница 18: ...acing of LBP panel is X x Y 20 32mm x 19 05mm 8 3 Connectors LBP Panels 8 3 1 Power Connector for 12 V DC supply 4 Pin connector MC 1 5 4 STF 3 81 locked with two screws Mounted on power supply delive...

Страница 19: ...led O2 O1 I2 I1 I_______I I_______I I_______I I_______I Dry Dry Input Gnd Input Gnd Relay Relay 0 12VDC 0 12VDC OUT No 2 OUT No 1 IN No 2 IN No 1 This Interface is a small signal interface only To avo...

Страница 20: ...of RJ 45 plugs to touch ground flange of RJ 45 connectors Wrong wiring wrong cables wrong use of twisted pair and non shielded traces lead to short working distances Bad connection at one of the core...

Страница 21: ...1 locked with two screws It is understood that if NOT using the original Power Supply Unit you need to make sure that there is only one single 12V DC supply with a maximum tolerance of 3 within the 12...

Страница 22: ...d standard shielded network cable CAT5 or higher standard To avoid potential difference between devices shielded cable and shielded plugs with ground potential on both sides should be used Metalized p...

Страница 23: ...an the button front of LBP panels is to use a soft cloth and smooth window cleaner fluid Do not expose the window cleaner directly to the buttons but to the cloth and then wipe softly over LBP panel f...

Отзывы: