background image

21

2. GENERATOR MAINTENANCE

Use a damp cloth to clean exterior    

surfaces of the generator. Use a soft 

brush to clean the dirt and oil. 

Use an compressed air (25 PSI) to clear 

dirt and debris from the generator. 

Inspect all air vents and cooling slots to 

ensure that they are clean and  

unobstructed.

WARNING

DO NOT use water to clean the generator. 

Water can enter the generator through the 

cooling slots and damage the generator 

windings.

DO NOT modify the generator in any way. 

DO NOT tamper with the governor. 

 

Generator supplies correct rated  

frequency and voltage when running 

at factory. Tampering with the factory   

governor will void your warranty.

3. ENGINE MAINTENANCE

ENGINE OIL

Only use four-stroke engine oil of SJ, SL or 

equivalent level which are in accordance 

with or higher than API standard. 

Check the API label on oil bottle or other 

container, and make sure the “SJ, SL” or 

equivalent level letter is in the label. 

SAE 1 0W-30 is recommended for general, 

all-temperature use. Other viscosities 

shown in the chart may be used when the 

average temperature in your area is within 

the indicated range.

Oil capacity {rated):  

See parameters  

Add oil

A. Place the engine on a level Surface.

B. Remove the dipstick and wipe it clean.

C. Add recommended oil to the upper 

limit.

Содержание BQH2000

Страница 1: ...INVERTER GENERATORS SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT BQH2000 BQH2200 A...

Страница 2: ...OR 9 MANUAL START 10 ELECTRIC START 11 WIRELESS REMOTE CONTROL 12 CONNECT TO ELECTRIC DEVICES 13 LOADING CAPACITY 14 WATTAGE REFERENCE CHART 15 STOPPING THE GENERATOR 16 PARALLEL CONNECTION IV MAINTEN...

Страница 3: ...t in property damage CAUTION Indicates a hazardous situation which if not strictly complied with could result in property damage or injury The warnings and precautions discussed in this manual cannot...

Страница 4: ...g or transporting the generator Keep fire extinguisher handy at all times Battery Lithium battery is maintenance free if you have any question please contact a local authorised dealer Hot Surface Runn...

Страница 5: ...n especially if the generator is equipped with a wheel kit Consult an electrician for local grounding requirements Installation should be performed by a certified electrician Improper Installation can...

Страница 6: ...6 EnergySavingSwitch 7 V TypeDCOutput 8 GroundTerminal 9 CircuitBreaker 10 EuroReceptacle 11 Parallel KitTerminal 12 Two In OneSwitch EngineStop Fuel Switch 13 PushButtonStart 1 CarryingHandle 2 Fuel...

Страница 7: ...power of the connected electric devices to the rated output range of the generator 2 Check the air intake for impurities and check the control parts for any abnormalities handle immediately if necessa...

Страница 8: ...tarting currents GROUNDING TERMINAL The grounding terminal is designed to prevent electric shock by connecting it to the grounding wire The generator must be properly grounded before operation TWO IN...

Страница 9: ...CAP Remove the fuel tank cap by rotating it anticlockwise VENTILATION KNOB The fuel tank cap is equipped with the ventilation knob to prevent leakage of fuel The ventilation knob must be in ON positi...

Страница 10: ...local dealer for high altitude kit information if you intend to operate the unit at altitudes above 5 000 feet 1 500 meters CAUTION Even with carburetor modification generator horsepower will decrease...

Страница 11: ...el Level should be between the upper and lower limit Fill to the upper limit of the dipstick with the recommended oil if the oil level is too low Reinstall and fully tighten the dipstick Reinstall the...

Страница 12: ...l above the upper limit mark Always allow room for fuel expansion Fuel capacity rated See parameters NEVER use engine or carburetor cleaner products in the fuel tank or permanent damage may occur It i...

Страница 13: ...in the generator or in connected electrical devices especially when the unit is equipped with a wheel kit Proper grounding also helps dissipate static electricity which often builds up in ungrounded d...

Страница 14: ...the engine grasp the recoil starter handle and pull slowly until resistance is felt Then pull rapidly to start the engine When pulling the recoil starter firmly grasp the carrying handle to avoid tum...

Страница 15: ...please release the switch button Do not attempt to start the engine again before figuring out the cause s Modification or using other battery to start the engine is not allowed If the engine speed is...

Страница 16: ...generator is connected to an electric device and the electric device is in ON state 12 CONNECT TO ELECTRICAL DEVICES 1 Inspect power cord for damage prior to use A damaged power cord is a hazard and...

Страница 17: ...tarting watts necessary for your purposes A Count the electrical devices you will power at the same time B The amount of power you need to run with the devices is the total rated running watts of thes...

Страница 18: ...eks please turn the knob to OFF position or the battery will be out of power and the generator can not be started 3 Turn the energy saving switch to the ON position 4 Allow the generator to run at no...

Страница 19: ...The total power of electric devices cannot exceed the rated power of the generator The manufacturers of electric devices or tools always list the rated power of similar models or serial numbers IV MAI...

Страница 20: ...at area Follow the service intervals indicated in the chart below Service your generator frequently when operating in adverse conditions Contact your local authorised service dealer for generator or e...

Страница 21: ...t rated frequency and voltage when running at factory Tampering with the factory governor will void your warranty 3 ENGINE MAINTENANCE ENGINE OIL Only use four stroke engine oil of SJ SL or equivalent...

Страница 22: ...when changing the oil to prevent burns A Place the machine on a level surface which is 300mm higher than the ground B Remove the oil maintenance cover C Place the waste oil box on the ground D Remove...

Страница 23: ...er unit I Assemble the filter fix clamp J Reinstall the appearance cover WARNING DO NOT run the engine without the air filter or serious danger can result SPARK PLUG A Clean any dirt from the spark pl...

Страница 24: ...k arrester if it is damaged F Reinstall the spark arrester in the muffler and reinstall the muffler blind window V STORAGE TRANSPORTATION STORAGE The generator should be started at least once every 2...

Страница 25: ...the engine switch OFF The two in one switch should be turned OFF WARNING Do not overfill the tank Do not operate the generator while it is on or inside a vehicle Take the generator off the vehicle and...

Страница 26: ...26 VI TROUBLESHOOTING...

Страница 27: ...27 VII SPECIFICATIONS 1 SPECIFICATION PARAMETER TABLE...

Страница 28: ...28 VII SPECIFICATIONS Note The generator with different specification and configurations may have different parameters and may change at any time without notice...

Страница 29: ...29 VII SPECIFICATIONS 2 WIRING DIAGRAM RECOIL STARTING...

Страница 30: ...30 VII SPECIFICATIONS ELECTRIC STARTING NOTE Because of the differences in generators the wiring diagram is only for reference...

Страница 31: ...Master Dealers have access to special tools training and genuine parts that are required to maintain your LawnMaster product for peak operating conditions The purchaser must keep an accurate record of...

Страница 32: ...faces deterioration of plated surfaces deterioration of rubber and plastics including rusting due to the passage of time Normal phenomena such as noise vibration and or oil are considered by Steelfort...

Страница 33: ...etc Any normal wear or deterioration such as that of sliding and or rotating parts caused under normal operating conditions i e normal wear to pistons piston rings cylinder bores piston pins valve sea...

Страница 34: ...rivate Bag 11045 Palmerston North 4442 New Zealand 06 350 1350 steelfort co nz steelfortnz SCAN TO VIEW THE LAWNMASTER RANGE Steelfort Auckland 880 Great South Road Penrose Auckland 1061 New Zealand 0...

Отзывы: