background image

Model Numbers

FF 45 / FF 70 / FF 125 / 

FF 175 / FF 215

© 2017 Lavorwash Australia Pty Ltd

7/76 Rushdale Street, Knoxfield, Vic.  3180

User’s Manual & 

Operating Instructions

CONSUMER: READ AND SAVE THESE INSTRUCTIONS

GENERAL HAZARD WARNING:

READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL 

BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. 

Be sure to comply with the 

instructions and warnings provided with this heater. Failure to comply can result in fire or explosion 

that can cause property loss, bodily injury, or loss of life. Only persons who can follow and 

understand these instructions should operate or service this heater. 

DANGER

NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES 

WITHOUT ADEQUATE VENTILATION. INDOOR USE PERMITTED ONLY FOR 

THE TEMPORARY HEATING OF BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, 

ALTERATION OR REPAIR. 

This is an unvented portable heater that uses air (Oxygen) from within 

the area in which it is used.  Failure to provide adequate combustion and ventilation air will result in 

asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 7.

DANGER

This appliance shall be installed in accordance with the rules in force, 

and used only in sufficiently ventilated space. Consult instructions before 

installation and use of this appliance. 

WARNING

FACTORY ID: 001

LWKA-400

Содержание FF 45

Страница 1: ...these instructions should operate or service this heater DANGER NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION INDOOR USE PERMITTED ONLY FOR THE TEMPORARY H...

Страница 2: ...G INSTRUCTIONS Failure to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot product...

Страница 3: ...foot 2 800 sq cm opening of outside air for every 100 000 Btu Hr heater rating Refer to Ventilation on page 7 for further instructions ALWAYS use only the electrical power voltage and frequency speci...

Страница 4: ...0VAC 50Hz 230VAC 50Hz 230VAC 50Hz Phase Single Single Single Single Single Specifications subject to change without notice Hot Air Outlet Upper Shell Lower Shell Fuel Tank Fan Guard Pressure Gauge Fue...

Страница 5: ...y 1 Align holes in the upper housing with the 2 holes in the handle as shown in Figure 3 2 Insert screws and tighten firmly Cord Wrap Assembly 1 Insert tabs into square slots in shell support and line...

Страница 6: ...ded Phillips Head Screw Driver 8 mm open end wrench 19 mm open end wrench Assembly Instructions Models FF 125 FF 175 FF 215 What s In The Box Tires 2 Axle Nuts 2 Spacers 2 Spare Drain Plug 1 Front Han...

Страница 7: ...rear handle with 2 long screws 50 mm and 2 nuts through the third hole from the rear of the heater on either side See Figure 6 8 Tilt the heater up gently so it is resting on the front handle NOTE DO...

Страница 8: ...er store paraffin in a red container Red is associated with gasoline Ventilation Risk of indoor air pollution and Carbon Monoxide Poisoning Use heater only in well ventilated areas Refer to Safety Inf...

Страница 9: ...perature setting The thermostat set range is from 4 5 C to 43 4 C 3 Move power switch to On position The power indicator light and room temperature display will illuminate and heater will ignite See F...

Страница 10: ...rvice DO NOT TAMPER WITH THE UNIT HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe...

Страница 11: ...ated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models FF 45 FF 70 turn filter 90 clockwise To remove the filter from models 125 175 FF 215 turn filt...

Страница 12: ...8 0 PSI 0 55 BAR Tolerance 10 NOZZLES Nozzles should be cleaned or replaced at least once per heating season Contaminated fuel could make this necessary immediately To clean dirt from nozzle blow comp...

Страница 13: ...plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh paraffin 7 Inspect all electrical connections See wiring diagrams on page 11 8 Re attach ignitor wire to spa...

Страница 14: ...URCE 2017 Lavorwash Kerosene Forced Air Heater User s Manual 13 17 14 16 11 15 12 40 42 46 34 4 19 17 3 5 35 8 7 1 2 9 28 29 27 32 21 22 23 31 26 30 24 18 55 47 49 50 39 38 6 45 44 43 36 10 41 20 33 3...

Страница 15: ...102 70 054 0102 70 054 0102 27 Output Filter 70 023 0100 70 023 0100 70 023 0100 70 023 0100 70 023 0100 28 Intake Filter 70 054 0101 70 054 0101 70 054 0101 70 054 0101 70 054 0101 29 End Filter Cove...

Страница 16: ..._______________________________________________ ____________________________________________________________ ____________________________________________________________ ______________________________...

Отзывы: