Rev A 07132018
Page | 3
Mounting the units
STEP 1:
Use the backplate as a template to mark the mounting
hole pattern. Drill a hole for the supplied ¼
”
anchors and mount the
bracket with the screws provided in the accessory kit.
STEP 2:
Attach the system to the backplate and slide it down. The
tab will make a clicking noise when the dispenser secured.
STEP 3:
Slide in the discharge hose (6.5ft or
“
S
”
tube) over the
barbed fitting and make sure it is secured.
STEP 4:
Connect the water inlet supply.
STEP 5:
Select the metering tip for your desired dilution and
connect the supply tubing.
STEP 6:
Connect the ceramic weight on the opposite end of the
tube with the foot valve.
1
2
3
5
6
After mounting the backplate, follow these instructions:
STEP 1:
Slide the second bracket into the slot from top to bottom on the left side of bracket 1 until they
are properly aligned and secure.
STEP 2:
Unlock the left side of the first system by pulling the rear clip to its outward most position as
shown and remove the end cap.
STEP 3:
Unlock the right side of the second system by pulling the clip to its outward most position and
remove the water connection.
STEP 4:
Insert the coupling nipple into the first unit as illustrated
STEP 5:
Connect the second unit to the first
STEP 6:
Apply the combined system on to the bracket and complete the installation as per step number
3 above.
Multiple Unit Installation:
4