![LAVAZZA Blue LB 2000 Скачать руководство пользователя страница 49](http://html2.mh-extra.com/html/lavazza/blue-lb-2000/blue-lb-2000_maintenance-manual_3914207049.webp)
M
ANUAL CODE
83356 / R
EL
. 0.00 / M
ARCH
2005
“LB 2000 OFFICE COFFEE SERVICE”
7
5/12
Test mode
Line 4
In this line the relative values of the components in their activated state can be seen.
Level "L1” shows: Torque XX (XX is a value referring to the force of the motor unit).
Level “L2” shows: Flow imp/s XX (XX is a value referring to the rotation of the flow
meter of the volume metering device).
Level “L3” shows: Temperature XX (XX is a value in degrees of the temperature of
the boiler).
Level “L5” shows: Contrast XX (XX is the value of the contrast of the display).
Level “L6” shows: LCD Light XX (XX is the value of the brightness of the display).
5 - LANGUAGE button (Language).
* Te s t M o d e L 1 *
1 2 3 4 5 6 7 8
1 2 3 4 5
To r q u e
**