Technical support maintenance manual
Rel. 0.00 / February 2020
31
Figure B
: remove the four water
connections, after pull outing the
clips present.
F
Warning
Pay attention to the position of
the tubes during reassembly.
Figure C
: lift the indicated tab and
pull out the ceramic valve (
1
).
12.4. DISMANTLING THE WATER LEVEL CAPACITIVE SENSOR
Figure A
: disconnect the wiring
from the CPU BOARD, by lifting
the indicated fixing tab and take
out the optical sensor, taking care
to gently pull out the electrical
connection.
B
C
1
A