12
PRECAUTIONS
PRECAUTIONS
SAFETY CHECK
WARNING : ONLY AN AUTHORIZED GAS TECHNICIAN SHOULD INSTALL THIS PRODUCT.
THE INSTALLER IS RESPONSIBLE FOR PROPER ASSEMBLY.
Annual check operation:
a. Unscrew the bolts on the observation
window panel, and remove the panel.
b. Turn on LP gas cylinder valve.
c. Spoon several drops (or use squirt bottle) of
the soap solution onto gas hose connection
and automatic valve connetion and the
injector connection.
d. Inspect the connections and look for
bubbles.
e. If no bubbles appear, the connection is safe.
f. If bubbles appear, there is a leak. Shut off the
LP gas cylinder valve, loosen and then
re-tighten this connection.
g. Check for leaks again.
h. If bubbles still appear, close the LP gas
cylinder valve and call our customer service
line. Do not attempt to use the heater.
i. Hose checking step:
(1) Remove the regulator from hose/regulator
connection.
(2) Remove M5x10 (4pcs) bolts, and then pull
out the hose from the pole.
(3) Visually check the hose to find if there
is a crack on the hose. If it has one,
replace the hose immediately.
(4) Repeat steps 1-3 after replacing the hose.
observation window
bolt
injector
connection
gas hose
connection
gas hose
connection
M5 x 10 bolt