background image

HEATER STAND AND LOCATION 

 

  The heater is for outdoor use only. Always ensure that adequate 

fresh air ventilation is provided. 
Always maintain proper clearance to combustible materials. 

 

  Heater must be placed on level firm ground. 

 

  Never operate heater in an explosive atmosphere like in areas where 

gasoline or other flammable liquids or vapors are stored. 

 

  Keep a distance of at least 2 metres from Combustible Materials. 

 

  After every use, turn off the gas valve on the cylinder. 

 

  The heater should be protected from strong winds by braking the wheel 

 

GAS REQUIREMENTS 

 

  Use liquid propane gas only. 

 

  The pressure regulator and hose assembly to be used must conform to local standard 

codes. 

 

  The installation must conform to local codes, or in the absence of local codes, with 

the standard for the storage and handling of liquid petroleum gases. 

 

  A  dented,  rusted  or  damaged  propane  tank  may  be  hazardous  and  should  be 

checked  by  your  tank  supplier.  Never  use  a  propane  tank  with  a  damaged  valve 
connection. 

 

  The  propane  tank  must  be  arranged  to  provide  for  vapor  withdrawal  from  the 

operating cylinder. 

 

  Never connect an unregulated propane tank to the heater. 

 

 

LEAKAGE TEST 

Gas connections on the heater are leak tested at the factory prior to shipment. A complete 
gas tightness check must be performed at the installation site due to possible mishandling 
in shipment or excessive pressure being applied to the heater. 

 

  Make  a  soap  solution  of  one  part  liquid  detergent  and  one  part  water.  The  soap 

solution can be applied with a spray bottle, brush or rag. Soap bubbles will appear in 
case of a leak. 

 

  The heater must be checked with a full cylinder. 

 

  Make sure the safety control valve is in the OFF position. 

 

  Turn the gas supply ON. 

 

  In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas 

supply on and recheck. 

 

  Never do leak test while smoking. 

 
                                                                        6 
 

Содержание PANDORA Y7

Страница 1: ......

Страница 2: ...2 Parts list Y7 3 Assembly Procedures 4 Position logs and glass ball on the burner 5 Heater Stand and Location 6 Gas Requirements 6 Leakage Test 6 Lighting instructions 7 Storage 7 Cleaning and Care 7 Data badge1 8 Data badge2 9 Problems Check List 10 ...

Страница 3: ...k for leaks Do not use the heater until all connections have been leak tested Turn off the gas valve immediately if smell of gas is detected Do not transport heater while it is operating Do not move the heater after it has been turned off until the temperature has cooled down Control compartment burner and circulation air passageways of the heater must be kept clean Frequent cleaning may be requir...

Страница 4: ...Exploding Drawing Y7 2 ...

Страница 5: ...tom door damper 1 28 Pilot protector 1 9 Turn knob bracket 1 29 Top mesh 1 10 Turn knob 1 30 Top panel of combustion chamber 1 11 Outer middle decorated bar 1 31 Side tempered glass 2 12 Gas valve 1 32 Glass slot 1 13 Inner middle decorated bar 1 33 Front tempered glass 1 14 Inner piece 2 34 Pilot 1 15 Inner panel of Top back door 1 35 Pilot bracket 1 16 Outer panel of Top back door 1 36 Front sup...

Страница 6: ... STEP 2 Screw the knob on tank door with screw we supplied in one set Use 2 pcs of M8 screw to contact handrail with heater body STEP 3 STEP 4 if go with back wheel Screw four wheels on heater body two wheel without brake for front side and two for behind Position top space mesh on the top board then screw it on 4 ...

Страница 7: ...osition ceramic logs on the burner Pandora Y7 1 Take out ceramic logs decorated oblate glass ball from carton 2 Refer to following picture for position the ceramic logs and decorated oblate glass ball 5 ...

Страница 8: ...ses A dented rusted or damaged propane tank may be hazardous and should be checked by your tank supplier Never use a propane tank with a damaged valve connection The propane tank must be arranged to provide for vapor withdrawal from the operating cylinder Never connect an unregulated propane tank to the heater LEAKAGE TEST Gas connections on the heater are leak tested at the factory prior to shipm...

Страница 9: ...linder valve or regulator switch to the OFF position and then turn the control knob on the appliance clockwise to the OFF position WARNING If the burner fails to ignite turn the control knob off clockwise and also turn the cylinder valve off Wait five minutes before attempting to relight with ignition sequence CLEANING AND CARE Make sure all the cleaning is done after turn off the heater and cooli...

Страница 10: ...CE IS NOT FOR DOMESTIC USE WARNING ACCESSIBLE PARTS MAY BE VERY HOT KEEP YOUNG CHILDREN AWAY READ THE INSTRUCTION LITERATURE BEFORE USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS AND LOCAL REGULATIONS CLOSE THE VALVE OF THE GAS CYLINDER OR THE REGULATOR AFTER USE THE USE OF THIS APPLIANCE IN ENCLOSED AREAS CAN BE DANGEROUS AND IS PROHIBITED WELL VENTILATED ...

Страница 11: ...WARNING ACCESSIBLE PARTS MAY BE VERY HOT KEEP YOUNG CHILDREN AWAY READ THE INSTRUCTION LITERATURE BEFORE USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS AND LOCAL REGULATIONS CLOSE THE VALVE OF THE GAS CYLINDER OR THE REGULATOR AFTER USE THE USE OF THIS APPLIANCE IN ENCLOSED AREAS CAN BE DANGEROUS AND IS PROHIBITED WELL VENTILATED AREAS MUST HAVE A MINIMUM O...

Страница 12: ...10 ...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Отзывы: