HEATER STAND AND LOCATION
The heater is for outdoor use only. Always ensure that adequate
fresh air ventilation is provided.
Always maintain proper clearance to combustible materials.
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in areas where
gasoline or other flammable liquids or vapors are stored.
Keep a distance of at least 2 metres from Combustible Materials.
After every use, turn off the gas valve on the cylinder.
The heater should be protected from strong winds by braking the wheel
GAS REQUIREMENTS
Use liquid propane gas only.
The pressure regulator and hose assembly to be used must conform to local standard
codes.
The installation must conform to local codes, or in the absence of local codes, with
the standard for the storage and handling of liquid petroleum gases.
A dented, rusted or damaged propane tank may be hazardous and should be
checked by your tank supplier. Never use a propane tank with a damaged valve
connection.
The propane tank must be arranged to provide for vapor withdrawal from the
operating cylinder.
Never connect an unregulated propane tank to the heater.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete
gas tightness check must be performed at the installation site due to possible mishandling
in shipment or excessive pressure being applied to the heater.
Make a soap solution of one part liquid detergent and one part water. The soap
solution can be applied with a spray bottle, brush or rag. Soap bubbles will appear in
case of a leak.
The heater must be checked with a full cylinder.
Make sure the safety control valve is in the OFF position.
Turn the gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas
supply on and recheck.
Never do leak test while smoking.
6