12
OPERATION INSTRUCTIONS
Leak Check
1. Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
2. Apply several drops of solution where hose attaches to regulator.
3. Apply several drops of solution where regulator connects to cylinder, apply the soapy solution to
all hose & valve connections.
4. Make sure all patio heater and light valves are OFF.
5. Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
1. Turn cylinder valve OFF.
2. If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles
continue appearing, the hose should be returned to the place of purchase,
3. If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak
check. Apply the soapy solution to all hose & valve connections. If you continue to see bubbles after
several attempts, cylinder valve is defective and should be returned to cylinder’s place of purchase.
If NO bubbles appear at any connection, the connections are secure.
NOTE:
Whenever gas connections are loosened or removed, you must perform a complete leak test.
4. Complete installation.
Regulator / Cylinder
connection
Hose / Regulator
connection
WARNING
3HUIRUPDOOOHDNWHVWVRXWGRRUV
([WLQJXLVKDOORSHQIODPHV
1(9(5OHDNWHVWZKHQVPRNLQJ
'RQRWXVHWKHKHDWHUXQWLODOOFRQQHFWLRQVKDYHEHHQ
leak tested and do not leak.
Содержание LAVA 2G
Страница 22: ......