WARNING: RISK OF HYPERTHERMIA AND POSSIBLE DROWNING, WATER
TEMPERATURE IN EXCESS OF 38®C MAY BE INJURIOUS TO YOUR HEALTH. CHECK AND
ADJUST WATER TEMPERATURE BEFORE USE.
WARNING: RISK OF HYPERTHERMIA, PEOPLE USING MEDICATION AND/OR HAVING AN
ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A
HYDROMASSAGE BATHTUB EQUIPPED WITH HEATER.
-For Indoor use only, Use unit only for its intended use as described in this manual.
-Install in accordance with the Manufacturer’s Installation instructions.
-Use supply wires suitable for 20A OC.
-Connect only to a circuit protected by a Class A ground fault circuit interrupter.
-Connect only to a branch circuit protected by and over current protection device
rated not more than 20A.
-Bonding lugs use copper conductors only.
(For permanently connected units) A green-colored terminal (or a wire connector Marked “G”,
“GR”, “Ground,” or “Grounding”) is provided within the terminal compartment. To reduce the
risk of electric shock, connect this terminal or connector to the grounding terminal of your
electric service or supply panel (SEE WIRING DIAGRAM PAGE 7) with a conductor Equivalent in
size to the circuit conductors supplying this equipment.
Do not use attachments not recommended by the manufacturer.
Never drop or insert any object into any opening
Do not operate this unit without the guard over the suction fitting.
The unit must be connected only to a supply circuit that is protected by a ground-fault Circuit-
interrupter (GFCI). Such a GFCI should be provided by the installer and needs to be tested on
a routine basis in ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.
(For permanently connected units) A green-colored terminal (or a wire connector Marked “G,”
“GR,” “Ground,” or “Grounding”) is provided within the terminal Compartment. To reduce
the risk of electric shock, connect this terminal or connector to the grounding terminal of your
electric service or supply panel with a conductor equivalent in size to the circuit conductors
supplying this equipment.