- 21 -
Storage after use
Note: The system must be stored in an
upright or fl at position and not on its side.
• Check that any condensation under the ironing board cover
has dried before storing away.
Caution: If the system is stored horizontally, the water reser-
voir must be emptied.
• Switch off and remove plug from the mains (
A
).
• Remove the warm SOFT PRESSING soleplate (
B
).
• Pull out steam cord holder and store (
C
).
• Store warm iron and close storage box (
D
).
• The ironing board is easiest to fold away when the board is
at its highest setting (
E
).
Rinse Boiler
Frequency:
before initial use and every month (or every 10
hours of ironing).
BEFORE using the appliance, rinse the
boiler when cold, switched off and
unplugged.
Danger: Risk of burns when the boiler is under pressure.
If rinsing the boiler AFTER using the appliance, you must
switch the appliance off, remove the mains plug from the
wall socket and wait at least 2h30 before opening the boiler
inlet and drain caps. Hold at a safe distance when opening
the caps.
Warning: Splashing water - protect delicate fl oor coverings.
Never use decalcifi er or other chemical products.
• Adjust the board to its highest position and remove the cold
water reservoir.
• Unscrew the boiler inlet cap (
F
).
MAX
G
F
H
A
B
C
D
E