LAUNCH
X-431 PROS V
1.0
User Manual
37
Tap it to start recording the sample data (
Note: Only data stream items with
measurement units will be recorded
), the following screen will appear:
Once the recording process is complete, tap
to stop it and navigate to the
data revision screen.
Tap the Min./Max. value to change it. After modifying all desired items, tap
Save
to save it as a sample DS file. All DS files are stored in
User Info -> Data
Stream Sample
.
E. Actuation Test
This option is used to access vehicle-specific subsystem and component tests.
Available test vary by vehicle manufacturer, year, and model.
During the actuation test, the display tablet outputs commands to the ECU in
order to drive the actuators, and then determines the integrity of the system or
parts by reading the ECU data, or by monitoring the operation of the actuators,
such as switching an injector between two operating states.