- 18 - 

 

 

After recovery, it will automatically enter the vacuum procedure. 

 

 

After the vacuum is complete, the equipment will sound a beep, and start to maintain 
pressure. If there is no leakage in the pipeline, you could skip this procedure and fill 
the  refrigerant  oil  into  refrigerant  cylinder  manually.  Long  press  “OK”  to  fill  and 
release to stop. After filling, press “Exit”. 

Содержание VALUE-500

Страница 1: ...s instead of Launch original products or Launch recognized products Declaration Other product names mentioned in the user manual are aimed to describe the device usage The registered trademarks still...

Страница 2: ...VALUE 500 Mobile Refrigerant Recovery Recycling and Charging Unit Touchscreen Version...

Страница 3: ...own below 6 H i g h a n d L o w P r e s s u r e V a l v e s O p e r a t i n g G u i d e l i n e s 7 Preparation Before Use 9 Operation Procedures 9 I Refrigerant Cylinder Refill 9 II Recycle 10 III Va...

Страница 4: ...essure of external factors 7 To ensure the refill function refrigerant cylinder must contain no less than 3kg refrigerant otherwise the refill may fail 8 Bubbles are always produced while discharging...

Страница 5: ...refrigerant cylinder of the equipment and during the recovery the refrigerant is purified and regenerated Vacuum It can evacuate any remaining gas or water from the equipment and the system Recharge...

Страница 6: ...3...

Страница 7: ...4 Appearance Introduction 1 Outside View 2 Rear View Handle AC 220V Fuse Vial filling valve Remove the retaining screw before using Power switch...

Страница 8: ...5 3 Side View 4 Operation Panel Refrigerant oil inlet Used oil bottle Low Pressure Valve High Pressure Valve Window Touchscreen...

Страница 9: ...5 Internal Structure Picture1 Picture2 Heat exchanger Condenser Cooling fan Filling valve for internal refrigerant cylinder Dry filter Vacuum pump Compressor Oil discharge solenoid valve Oil separato...

Страница 10: ...ction to Car as shown below Filling pipe ball valve Electronic scale protection screw Filling pipe red Recycling pipe blue Recycling pipe ball valve Electronic scale for internal liquid reservoir Inte...

Страница 11: ...Turn off the high and low pressure valves As shown below turn off the high low pressure valve is to tighten the valves counterclockwise based on the reverse direction of the arrow the arrow marked op...

Страница 12: ...kwise based on the direction of the arrow the arrow marked open on the valve on the high and low pressure valves Rotate the air conditioning quick couplings clockwise Sketch map of turning on the air...

Страница 13: ...ng the factory Refrigerant must be refilled before operation The recommended refill weight is 3 6kg Operation is as follows 1 Attach the blue hose to the main equipment s low pressure valve 2 Attach t...

Страница 14: ...and click Confirm to continue After the procedure completed normally the system shows the following interface click Exit to return to main interface 2 Recycle Recycle is recycling the purged refriger...

Страница 15: ...us to set time then select run Any refrigerant in the pipeline would be recycled automatically then the vacuum procedure would start Dwell time comes after vacuum procedure As the time ends it enters...

Страница 16: ...s OK to start and release to stop Exit the system upon completion 4 Charge On the homepage double click charging to enter the filling procedure You can select the large or the small bottle filling Aft...

Страница 17: ...quipment pipelines Press exit upon completion 5 Purge Purge function is to clean the car piping system Enter the cleaning procedure press plus or minus to add or reduce the forward and reverse cleanin...

Страница 18: ...15...

Страница 19: ...16 After cleaning is complete it will automatically enter the recycling procedure Press exit upon completion 6 Quick Maintenance On the homepage click Fast Service to enter the procedure...

Страница 20: ...e forward and reverse cleaning time and to set the number of cycles Before cleaning ensure that there is more than 2KG refrigerant in the tank then press OK to start After the cleaning is complete it...

Страница 21: ...cuum is complete the equipment will sound a beep and start to maintain pressure If there is no leakage in the pipeline you could skip this procedure and fill the refrigerant oil into refrigerant cylin...

Страница 22: ...e or the small bottle filling After selecting the fill mode ensure that there is sufficient refrigerant Then long press OK to start and release to stop After completion press EXIT it will automaticall...

Страница 23: ...20 Press exit upon completion 7 Equipment Maintenance Click Equipment Maintenance in the main interface to enter the maintenance procedure...

Страница 24: ...ale First input the weight of reference weight parameter 2000g for example Then click OK and go on to the next step Place 2kg weight should be equal to the weight input in previous step on the tray Wa...

Страница 25: ...22 Electronic Scale Reset Ensure there is no refrigerant inside the cylinder Wait until weight parameter become unchanged and click OK to finish intelligent reset Equipment Information...

Страница 26: ...23 Filter Parameter After the replacement of filter enter the interface of filter parameter Enter the password and reset the service time of the filter...

Страница 27: ...ation presentation or promise related to Launch products Statement of Disclaimer The above warranty clause can substitute for any other form of warranty clauses Purchase Order Replaceable parts and op...

Страница 28: ...may differ from those shown in the manual Please refer to the actual product We have tried our best to make all the descriptions in the book accurate but there are still some inconveniences If you ha...

Отзывы: